279
17 Printing
17.4
17
.
GC-2014
17.4
Event No.
Many parameters are printed with event No. The list below shows the correspondence of event
No. to functions.
Q
Event No. list
No.
Meaning of “Event xx” (Example: Event 1)
Meaning of “Event-xx” (Example: Event -1)
0
Reverses contact status of Events 1 to 16 and
Events 91 to 96.
Opens contact of Events 1 to 16 and switches
contact of events 91 to 96 to N/C type (normal).
1
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
2
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
3
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
4
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
5
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
6
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
7
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
8
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
9
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
10
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
11
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
12
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
13
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
14
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
15
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
16
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
51
Performs zero adjustment of DET #1.
Frees zero adjustment of DET #1.
52
Performs zero adjustment of DET #2.
Frees zero adjustment of DET #2.
53
Performs zero adjustment of DET #3.
Frees zero adjustment of DET #3.
54
Performs zero adjustment of DET #4.
Frees zero adjustment of DET #4.
61
Turns on CAR1 gas saver.
Sets split ratio to value of CAR1 gas saver split
ratio 1.
Turns off CAR1 gas saver.
Returns split ratio to value of analysis
parameter.
Содержание GC-2014
Страница 4: ...This page is intentionally left blank ...
Страница 12: ...Contents viii GC 2014 This page is intentionally left blank ...
Страница 28: ...1 Installation 1 3 Gas Supply Plumbing 16 GC 2014 This page is intentionally left blank ...
Страница 42: ...2 Before Use 2 6 Connecting the Relay Terminals 30 GC 2014 This page is intentionally left blank ...
Страница 78: ...5 Analysis 5 2 Notes for Analysis 66 GC 2014 This page is intentionally left blank ...
Страница 90: ...6 Basic Key Operation 6 4 Getting Help 78 GC 2014 This page is intentionally left blank ...
Страница 130: ...11 Creating an Oven Temperature Program 11 2 Temperature Programs 118 GC 2014 This page is intentionally left blank ...
Страница 164: ...12 Injection Port 12 5 Setting the Flow Rate Parameters 152 GC 2014 This page is intentionally left blank ...
Страница 282: ...16 Special Functions 16 10 ROM Version No 270 GC 2014 This page is intentionally left blank ...
Страница 318: ...306 GC 2014 This page is intentionally left blank ...