BPS – K – 3.0 – 6.0
Sherpa
Autodiagnostik
page: 11
3.
Technical Information
3.1
Identification:
- The complete equipment of the test unit is identified by a type label on the control box as well as
by means of the following information on the roller set:
- manufacturer
-type and version
-serial number
- year of manufacture
- power in kW
-power supply in V and ACNPE -current consumption measured in A
- In addition, each unit (set of rolls, display, print box, etc.) has its own serial number.
3.1.1
The entire system
permissible humidity
up to 85 %
operating temperature
-10° to +60°
point zero adjustment when ready for operation
every 2 minutes
3.1.2
Display cabinet
housing dimensions width x depth x height (mm)
810 x 670 x 70
weight
10 kg
braking force display
0 - 6 kN (0 – 12)
diameter of the needle-analogue display
400 mm
subdivision
180°
smallest increment
100 N
type size
25 mm
3.1.3
Control box
power supply
3 x 400 V (AC)
permissible fluctuation of the nominal voltage
± 10 %
protection
3 x 20 Ampere slow
supply lead
5 x 2.5 mm²
3.1.4
Set of rolls compact
3.0 3.5 6.0
one-piece frame width x length x depth (mm) 2260 x 580 x 195
2320 x 680 x 240
2925 x 680 x 240
approx. weight in kg
290
440
640
length of rollers in mm
600
700
1000
diameter of rollers in mm
167
205
205
track gauge
820 x 2160
800 x 2200
800 x 2800
distance between the axes of the rollers
380
410 mm
400
crossing capacity on middle cap, max. wheel
load in kg
550
550
550
test speed in km/h
2.7
4.8
4.8
coefficient of friction dry / wet
0.9 / 0.7
measuring system, shear force transducer
DMS
with integrated measuring reinforcement
noise emission LWA
<70 dB (A)
welded roller surface
welding rod
measurable axle load (for a deceleration of
50%) in kg
2000
2000
2450 / (4800)
measurable axle load (option of 2x4 kW
motors) in kg
2450
max. axle load on rollers in kg, when vehicle
enters the test stand
3000
4000
5000 / (6000)
output of the driving engines in kW
2 x 2.4
2 x 3 kW
2 x 4
voltage supply in mm² / A
5 x 2.5 / 16
5 x 2.5 / 20
5 x 2.5 / 20