66/75
Electrical installation checking
1-Static values (engine off) 300 SEF-R (for 250 SEF-R, see 2013 workshop manual)
Tension battery : > 12.5V
A- Stator resistance
B-Pick up sensor : 120
Ω
±10%
Check there is no continuity between stator and the ground of the motorcycle
2-Dynamic values:
Pick up sensor:
1.7V MIN/300 tr/min
120V MAX/10000 tr/min
Regulator:
Alternative (200V alternative caliber)
Idle speed 22V ±2V
A 6000 rpm : 77V±3V
Continue
Regulator pins out (Caliber 20V continue)
A 4000 tr/min : 14.6V + Red/white, - Green
Y1-Y2
0.44
Ω
±15%
Y2-Y3
Y1-Y3
Содержание 2014 250 SEF-R
Страница 1: ...Workshop manual Workshop manual 2014 250 SEF R 300 SEF R Workshop manual...
Страница 41: ...41 75 Disconnect each connector Inspect Clean with carbu cleaner or universal product cleaner Blow...
Страница 69: ...69 75 300 SEF R 2014 Synerject EFI system cable diagram...
Страница 70: ...70 75 250 SEF 2014 light system cable diagram...
Страница 71: ...71 75 300 SEF 2014 light system cable diagram...
Страница 72: ...72 75 250 SEF R 2014 Racing light system cable diagram...
Страница 73: ...73 75 300 SEF R 2014 Racing light system cable diagram...
Страница 74: ...74 75 Flasher installation cable diagram...
Страница 75: ...75 75 Fan cable diagram...