5. Setup Contents in Each Category
[System Time] / [System Date]
•
Configuration for Time / Date in battery backup RTC. Arbitrary
Time / Date can be configured.
•
If RTC data is undefined, clock is initialized to time 00:00:00 and
date 1997-10-01
[IDE Adapter 0 Master] / [IDE Adapter 1 Master]
•
Configures HDD type.
•
IDE Adapter 0 Master is [Auto], IDE Adapter 1 Master is [None]
used for operation.
For connecting second HDD, set IDE Adapter 1 Master to [Auto].
By setting to Auto, default size of HDD is automatically detected at
BIOS bootup.
6. BIOS message on system startup
1) Message on system startup
(1): Sign on message
(2): Message when conventional memory check completes without
any errors.
(3): Message when extended memory check completes without any
errors.
2) Error message displayed when setup resumes
Following messages are displayed under
4
and below each mes-
sage, "Setup available" is displayed showing starting setup enabled.
Message
Error meaning
System battery is dead –
Replace and run SETUP
Backup cannot be done by
lithium battery.
System CMOS checksum bad –
run SETUP
Data in CMOS RAM is
corrupted
Real time clock error
Configuration in RTC is invalid.
3) Error message displayed when hardware is
unusual
Following messages are displayed if hardware is unusual. Following
table shows meaning of error messages displayed on different posi-
tions.
•
Message outputted by system RAM test (position
2
)
Message
Error meaning
Nnnn K System RAM
Failed at offset:nnnn
W/R error occured in conventional
memory at displayed address
nnnn K Shadow RAM
Failed at offset:nnnn
W/R error occured in Shadow RAM at
displayed address
Failing Bits:nnnn
Bit missing error occured by memory
test
•
Message displayed by Extended RAM test (position
3
)
Message
Error meaning
nnnn K Extended RAM
Failed at offset:nnnn
W/R error occured in extended
memory at displayed address
Failing Bits:nnnn
Bit missing error occured by memory
test
•
Message displayed by CPU cache test (position below
3
)
Message
Error meaning
System cache error –
Cache disabled
Error occured during cash test and
disabled cash
•
Message displayed by device test (position below
3
)
Message
Error meaning
System timer error
Timer chip (8254) error
Keyboard controller error
Error occured during KBC test
Keyboard error
Error occured during full keyboard
connection test
Diskette drive A error
FDD error
Incorrect Drive A type –
run SETUP
Floppy Disk is not operating normally
Failure Fixed Disk
HDD error
Missing or Invalid NV
RAM token
R/W error occured in CMOS RAM
•
Message displayed by parity error from bus (position undefined)
Message
Error meaning
Parity Check 1
Parity error (NMI) occured from
system bus
Parity Check 2
Parity error (NMI) occured from ISA
bus
*
NOTE
[Message displayed during OS bootup]
Operating system not found
•
Boot drive does not exist or OS is not written.
•
Make so that OS can be booted and restart the system.
1
2
3
4
PhoenixVIEW 4.0.1 VGA-Compatible BIOS -9903 Rev
MEI MN89305 SVGA Contoroler
Copyright (C) 1984-1998 Phoenix Technologies Ltd.
All Rights Reserved
Phoenix NoteBIOS 4.0.7
Copyright 1985-1998 Phoenix Technologies Ltd., All Rights Reserved
SHARP POS Terminal Firmware Version 1.0A
0000640K System RAM Passed
0007168K Extended RAM Passed
Fixed Disk 0: Identified
6 – 2
Содержание UP-5300
Страница 103: ... B S i d e 9 2 ...
Страница 104: ...2 M a i n P W B F o r c o m p o n e n t s p r o d u c e d i n F e b r u a r y 1 9 9 9 a n d o n w a r d A S i d e 9 3 ...
Страница 105: ... B S i d e 9 4 ...
Страница 106: ...3 V G A P W B A S i d e B S i d e 9 5 ...
Страница 107: ...4 R i s e r P W B A S i d e B S i d e 5 T P S w i t c h P W B S w i t c h P W B 9 6 ...
Страница 108: ...6 I N V E R T E R P W B A S i d e B S i d e 7 L C D R E L A Y P W B A S i d e B S i d e 9 7 ...