background image

 

 

Magnetic Stripe Reader 

SERIES 1290 

 

 

 

 

 

Operation Manual

 

Version 1.0 

Содержание MSR JC-1290 KB series

Страница 1: ...Magnetic Stripe Reader SERIES 1290 Operation Manual Version 1 0 ...

Страница 2: ...ed to try correct interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This booklet is available from the U S government Print...

Страница 3: ... JC 1290 USB Series 6 Chapter 3 Driver Installation 7 Chapter 4 Programming Tools 4 1 Install Programming Tool 10 4 2 Execution Programming Tool 15 4 3 Main Setting 20 4 4 MSR right side button function 21 4 5 Track 1 3 Setting 22 4 6 MSR ISO Standard Setting 23 4 7 Firmware Update 24 4 8 Switch Setting 26 Appendix I Specification 27 Troubleshooting 28 ...

Страница 4: ...MSR JC 1290 series User s Manual Appearance CHAPTER 1 3 RJ 45 Connector MSR 1290 ...

Страница 5: ...2 2 1 JC 1290 KB series The MD 6M side of KB cable shall be connected to PC PS 2 Keyboard port The MD 6F side of KB cable can be connected to normal PC keyboard PC keyboard can work with the product together 4 PS 2 Keyboard Touch POS 8802 JC 1290 Keyboard ...

Страница 6: ...MSR JC 1290 series User s Manual 2 2 JC 1290 RS232 series The DB 9F side of RS232 cable connects to PC COM port COM 1 or COM 2 or other COMs and power connects to USB 5 RS232 Touch POS 8802 JC 1290 ...

Страница 7: ...USB simulates RS232 and Keyboard interface by USB with COM port selected Following sections are MSR USB driver utilities installation MSR USB Driver a Download MSR USB Driver from CD and extract them to your hard disk b When you plug in the USB device WINDOWS operating system will detect the new Hardware automatically c Follow indicated steps to install the driver and finish the installation 6 OR ...

Страница 8: ...o you have to check the USB assigned COM port from Device Manager of windows operating system before you starting to get data from 1290USB 2 Use COM test software to open simulated com port Setting COM port as 9600 N 8 1 3 Swiping the magnetic card tracks data will be shown on the screen 7 JC 1290 KB series Standard PS 2 keyboard interface no driver needed JC 1290 RS232 series Standard com port in...

Страница 9: ...MSR JC 1290 series User s Manual 8 Please select the CP210xVCPInstaller exe When the setup screen appears than to select Install step ...

Страница 10: ...After installation complete select OK Please connect the 1290 USB RS232 to computer then check the device installed normally in device manager Silicon Labs CP210x USB to UART Bridge COM6 Notes COM number may be different on each computer ...

Страница 11: ...90_Programming_Tool_V1 exe When the setup screen appears than to select Next step 4 1 Install Programming Tool Note Please install Microsoft NET Framework 2 0 first Download Web site http www microsoft com downloads details aspx familyid 0856EACB 4362 4B0D 8EDD AAB15C5E04F5 displaylang zh tw ...

Страница 12: ...MSR JC 1290 series User s Manual 11 When the setup screen appears than to select Next step Please select I agree than to select Next step ...

Страница 13: ...MSR JC 1290 series User s Manual 12 When the setup screen appears than to select Next step When the setup screen appears than to select Yes ...

Страница 14: ...MSR JC 1290 series User s Manual 13 When the setup screen appears than to select Start step When the setup screen appears than to select Next step ...

Страница 15: ...MSR JC 1290 series User s Manual 14 After installation complete select Exit ...

Страница 16: ...MSR JC 1290 series User s Manual 15 Please click the File on the functionality Please Executive the 1290_programming_Tool 4 2 Execution Programming Tool ...

Страница 17: ...MSR JC 1290 series User s Manual 16 Please choose the device type first USB Keyboard is for example Please Click New to create a new file Please Click Open config File to open the saved file ...

Страница 18: ...MSR JC 1290 series User s Manual 17 Please Click Save to save the file Please Click Save As to save a another file ...

Страница 19: ...MSR JC 1290 series User s Manual 18 This function can programming device form a config file This function can save device setting to a config file ...

Страница 20: ...MSR JC 1290 series User s Manual 19 This function can reset device to default value Please choose whether to reset in this screen ...

Страница 21: ...hen MSR reading error Prefix Suffix Enable or disable prefix suffix for MSR data When the check box on you can edit the prefix suffix every fields in up to 7 characters Note The format of output data is MSR Prefix Track1 data Track2 data Track3 data MSR Suffix 4 3 Main Setting ...

Страница 22: ...Button is for write the data settings to MSR JC 1290 Set Default This Button is for set the data to default Load Key Setting This Button is for load the setting from MSR device Test This button is for show test window 4 4 MSR right side button function ...

Страница 23: ... Track 2 3 start sentinel is End sentinel Enable Disable track end sentinel The end sentinel is for all tracks LRC sentinel Enable Disable the LRC sentinel is the checksum character for the data of card track Left to Right decode and Right to Left decode You can make choice to decide the user to swipe card and read data only from left to right or from right to left or both ways i e Track1 data out...

Страница 24: ...e check box of Field Splitting Enable for ON then the data of card track will be outputted and follow the ISO standard fields You can set the Send CR or and Send LF for every ISO fields Block Format i e Track1 data output when ISO Field Splitting Enable Additional Data CC NAME Data FC PAN Data CR LF Track2 Track3 so on ...

Страница 25: ...e Update Special Note The JC 1290 provides new features update or modification from the programming tool Step 1 When you click Open File button will pop up the window select the BIN file then click Open Picture on the SS 1290001 10 bin is an example ...

Страница 26: ...1290 series User s Manual 25 Step 2 When the picture show on F W Version after the press Flash Firmware button to update Note Please do not power off the JC 1290 or removal the usb cable when updating firmware ...

Страница 27: ...redit Card Only Show Card number SW3 Auto Caps lock ON USB KB when Card data output Disable Auto caps lock ON SW4 Prefix suffix output in ASCII mode Prefix Suffix output in Scan code mode SW5 Enable Buzzer Disable Buzzer SW6 Software sets RS232 Baud RS232 Baud rate fix to 9600 SW7 Normal Operation Reset all settings to default SW8 Card Data output in ASCII mode Card Data output in Scan code mode 4...

Страница 28: ...0 RH non condensing EMC Safety FCC CE RoHS Class A ISO standard 7810 7811 7812 7813 Keyboard Wedge Interface IBM AT PS 2 Standard PS 2 Keyboard Environment Physical 115mm x 46mm x 34mm Package 238mm x 146nn x 47mm During operation max 100 mA While idle 30 mA Interface USB RS232 USB RS232 Mode MSR JC 1290 Card Reading Speed Black White Triple tracks Tracks 1 2 3 7 5 to 125 cm sec Bi directional RS2...

Страница 29: ...ere is no application program using the COM port Step 5 If the Beep sound is long short short it means the card reader can t read the data from the card Please check the card status in advance is available or change new card for testing Q3 1290 USB plug in to USB port there is no reaction Ans A Use other USB devices for testing the USB port is available or not B If the USB port is ok use new 1290 ...

Страница 30: ...from the keyboard data for testing such as Note pad Microsoft Word so on Q7 Installation of 1290 Series how about the normal Beep sound Ans Plug in the power supply it will have the response of sound Beep After 1290 device automatically checks 1290 will have 2 short sounds 1290 USB R will have 2 long sounds The led indicator will present Green If the sound is 1 short and 1 long sound the led indic...

Отзывы: