Default is all OFF
OFF
ON
SW1 Track data sets by software
Fixed track data output:
1. Fully track data.
2. Fixed prefix: Track1 “%” , Track2 “;” , Track3 “+”
3. Send [ENTER] (KB mode)
or <0Dh><0Ah> (RS232 mode) after each track.
SW2 Normal ISO Track 2
Track2 for Credit Card (Only Show Card number)
SW3 Auto Caps lock ON (USB-KB) when
Card data output
Disable Auto caps lock ON
SW4 Prefix/suffix output in ASCII mode
Prefix/Suffix output in Scan code mode
SW5 Enable Buzzer
Disable Buzzer
SW6 Software sets RS232 Baud
RS232 Baud rate fix to 9600
SW7 Normal Operation
Reset all settings to default
SW8 Card Data output in ASCII mode
Card Data output in Scan code mode
4-8. Switch Settings