(On the above screen, the thick figures are selected, and the thick
figure values are selected.)
On the above screen, when the pass count is counted up (when
point is counted up to the upper limit set in the cylinder range
setting, the pass count is counted up by 1.), and if the error
counter of all error items are not counted up (remaining as
00000), the test is OK.
3
Terminating method
The methods to interrupt, resume, and terminate the test are the
same as (2) Sequential read.
5) Target Sector Read Test
[Test conditions setting]
•
Cylinder range [0
∼
inmost cylinder]
The cylinder range to be tested is set.
•
Head count [0
∼
final head]
The head umber to be tested is set.
•
Sector count [0
∼
final sector]
The sector number to be tested is set.
•
Retry count [0
∼
4]
Retry number incase of an error is set.
•
Error stop/Continue/1 Pass
Selection is made among Error Stop/Continue/1 Pass in case
of an error.
•
Test start ? [Yes/No]
Selection is made between Yes/No of test start.
1
Checking content
A read is made for the cylinder range, the head number, and the
sector number areas set in the above.
When the read test is completed in the set range, it is counted as
1 pass.
In case of an error during the above test, a retry is repeated up to
the set number of retries. Every time when an error occurs a retry
is performed up to the set number of retries and, error logging is
made. Logging is made for HD and DRAM.
When the "Error Stop" is set in the test condition setting, and an
error occurs during the above test, the error display is shown and
the test is interrupted. Press the space key to resume the test.
When the "Continue" is set, even if an error occurs, the error
display is made but the test is not stopped.
When "1 Pass" is set, a series of tests is made only once and the
test is stopped.
2
Display
Select the desired items at the position of @. (@ is not displayed
on the screen.)
(On the above screen, the thick figures are selected, and the thick
figure values are selected.)
On the above screen, when the pass count is counted up (when
point is counted up to the upper limit set in the cylinder range
setting, the pass count is counted up by 1.), and if the error
counter of all error items are not counted up (remaining as
00000), the test is OK.
3
Terminating method
The methods to interrupt, resume, and terminate the test are
same as (2) Sequential read.
6) HD Dump Test
[Test conditions setting]
•
Cylinder No. [0
∼
inmost cylinder]
A certain cylinder No. to be displayed is set.
•
Head No. [0
∼
final head]
A certain head No. to be displayed is set.
•
Sector No. [1
∼
final sector]
A certain sector No. to be displayed is set.
1
Checking content
The sector set in the above is displayed on the screen in the unit
of 256byte.
Hex data and ASCII characters are displayed.
By key operation, the following 256 byte data or previous 256byte
data can be displayed.
2
Display
The physical address is set at the position of @. (On the above
screen, the thick value is set.)
On the above screen, the first-half 256 byte at 000 cylinder, 00
head, and 01 sector is displayed.
Press the page down key to display the second-half 256 byte.
(When the page down key is pressed on the above screen, the
second-half 256byte at 000 cylinder, 00 head, and 01 sector is
displayed.)
Press the page up key to display the first-half 256byte.
3
Terminating method
Press the Esc key to return to the menu screen of previous (1).
7) Error Information Display
1
Checking content
Error information stored in the inmost area of the HDD is dis-
played.
When the hard disk test is executed, error information stored in
the error information storing area is displayed.
The inmost cylinder, 0 head, and 1 sector
∼
6 sector are read to
be displayed.
2
Display
Every time the Enter key is pressed, the next page error informa-
tion is displayed.
Target Sector Read test
@Cylinder range ?
[000 XXX] = 000-XXX
(XXX is displayed by checking the
inmost cylinder.)
@Head count ?
[0 XX] = 0
(XX is displayed by checking the
final head.)
@Sector count ?
[0 XX] = XX
(XX 8s displayed by checking the
max. sector.)
@Retry count ?
[0 4] = 0
@[Errorstop continue 1pass]
@Test Start ? [Yes No]
Pass count = XXXXX
Test Point = CCC : HH : SS (Cylinder: head; sector)
Error Kinds
Drive not ready XXXX
Bad controller XXXX
Compare error XXXX
ESC : Exit SPACE : Stop or Start
Details of error are displayed.
HD Dump test
@Physical address ? [CCC. HH. SS] = 000. 00. 01
The first hslf sector
000 : HHHH......HHHH-HHHH......HHHH : AAA......AA
(100)
PGDN : forward PGUP : back SPACE : Start ESC : Exit
:
010 : HHHH......HHHH-HHHH......HHHH : AAA......AA
(110)
:
0F0 : HHHH......HHHH-HHHH......HHHH : AAA......AA
(1F0)
:
020 : HHHH......HHHH-HHHH......HHHH : AAA......AA
(120)
:
:
Error Logging information Display
Error
No.
001
002
003
004
005
006
007
ESC : Exit ENTER : Next
YY/MM/DD
99 / 03 / 01
HH : MM : SS
10 : 30 : 00
Cyl
No.
100
Hed
No.
03
Sec
No.
01
Error
Content
XXXXXXX
4 – 14
Содержание UP-5300
Страница 103: ... B S i d e 9 2 ...
Страница 104: ...2 M a i n P W B F o r c o m p o n e n t s p r o d u c e d i n F e b r u a r y 1 9 9 9 a n d o n w a r d A S i d e 9 3 ...
Страница 105: ... B S i d e 9 4 ...
Страница 106: ...3 V G A P W B A S i d e B S i d e 9 5 ...
Страница 107: ...4 R i s e r P W B A S i d e B S i d e 5 T P S w i t c h P W B S w i t c h P W B 9 6 ...
Страница 108: ...6 I N V E R T E R P W B A S i d e B S i d e 7 L C D R E L A Y P W B A S i d e B S i d e 9 7 ...