-110
Maintenance Indicators
Info
•
If the TEMPERATURE WARNING indicator illuminates, and the power turns off, follow the above possible
solutions and then wait until the projector has cooled down completely before plugging in the power cord and
turning the power back on. (At least 5 minutes.)
•
If the power is turned off and then turned on again, as during a brief test, the LAMP REPLACEMENT indica-
tor may be triggered, preventing the power from going on. Should this occur, take the power cord out of the
wall outlet and plug it back in again.
•
If you want to clean the air vents during projector operation, be sure to first press
and after the power has
turned off and the cooling fan has stopped, then clean the vents.
•
Do not unplug the power cord after the power has been turned off and while the cooling fan is running. The
cooling fan runs for about 90 seconds.
About the TEMPERATURE WARNING indicator
If the temperature inside the projector in-
creases, due to blockage of the air vents, or
the setting location, “
” will blink in the
lower left corner of the picture. If the tem-
perature keeps on rising, the lamp will turn
off and the TEMPERATURE WARNING in-
dicator will blink, the cooling fan will run for
further 90 seconds, then the power will be
shut off. After “
” appears, be sure to
perform the following measures.
■
The warning lights on the projector indicate problems inside the projector.
■
If a problem occurs, either the TEMPERATURE WARNING indicator or the LAMP REPLACEMENT
indicator will illuminate red, and the power will turn off. After the power has been turned off, follow
the procedures given below.
About the
LAMP
REPLACEMENT
indicator
■
When the lamp
exceeds 1,900 cumulative hours
of use, “
” will be displayed
on the screen in yellow. When
the cumulative hours of use
reach 2,000, “
” will
change to red, the lamp will au-
tomatically turn off and then the
projector as well. At this time, the
LAMP REPLACEMENT indica-
tor will illuminate in red.
■
If you try to turn on the projector
a fourth time without replacing
the lamp, the projector will not
turn on.
Maintenance indicator
Condition
Problem
Possible Solution
TEMPERA-
TURE
WARNING
indicator
Normal
Abnormal
Off
Red on/
Power off
The internal
temperature is
abnormally high.
Abnormal
•
Blocked air intake
•
Relocate the projector to an area
with proper ventilation.
•
Cooling fan break-
down
•
Internal circuit failure
•
Clogged air intake
•
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see
page
118
)
for repair.
LAMP
REPLACE-
MENT
indicator
Red on/
Power off
The lamp does
not illuminate.
•
Burnt-out lamp
•
Lamp circuit failure
•
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see
page
118
)
for repair or lamp replacement.
•
Please exercise care when
replacing the lamp (see
page
111
).
Green on
Green
blinks
when the
lamp is
active.
Red
blinks
Time to replace
the lamp
•
Lamp usage time
exceeded 1,900
hours
TEMPERATURE
WARNING
indicator
LAMP
REPLACEMENT
indicator
POWER
indicator
Содержание Notevision PG-M25X
Страница 4: ...SPECIAL NOTE FOR USERS IN EUROPE ...
Страница 25: ...Setup and Connections Setup and Connections ...
Страница 37: ...Basic Operation Basic Operation ...
Страница 69: ...Easy to Use Functions Easy to Use Functions ...
Страница 111: ...Appendix Appendix ...
Страница 131: ...SHARP CORPORATION ...