SHARP
REPAIR HINTS
65
SPECIFICATION
Model
Symptom
Advice
ALL
Is it possible to Tandem
MX-2640/3640N series with another
MX colour device?
Tandem operation is only supported with
MX-2640/3140/3640N series only.
Is it possible to retain the Destination
Address (Image Send Mode), once the
current Scan operation is complete?
To enable this function, change,
SIM55-03 SW30-3 from 0 (default) to 1.
Once enabled, go to System Settings-Image Send
Settings-Operation Settings menu and enable the “Hold
Address for a while after scanning is completed” option
for the relevant Image Send mode.
TROUBLE CODES
ALL
C4-00
To prevent static discharge (change of bias voltages),
upgrade the PCU firmware to 04.04.G2.00 (or higher).
Also check the operation of the Drum Phase sensors
and the clutches that change the position of the
Primary Transfer Belt . The belt may not be locking
securely into the colour or BW position.
PG Section 51, item 20 (x2). PCLC-0373FCZ1
U2-00
The latest Running Change firmware now supports
U2-00 cancellation therefore:-
1. Upgrade the MFP Firmware to 03.00.A2 (or higher).
2. Clear U2-00 trouble by executing SIM16.
MX-EB11
E7-47 trouble
To support MX-2640/3140/3640N series, the ACU
firmware version must be upgraded to 01.00.A2.
Use SIM49-10 to perform the ACRE firmware upgrade.
GENERAL / MISC
ALL
Error K, C, M, Y in Sim44-26 and/or
machine hangs in Sim46-74 when
trying to print the calibration sheet.
Check/replace CF card on the MFP PWB.
MFP fails to boot (or keeps rebooting)
Please ensure the CF Card is installed correctly.
Make sure it is seated all the way and "clicks" into
place.
No Output Tray Is Allowed error
message
The above message can be displayed if the machine
power is turned OFF just before the lift up of Tray 3 or
4 is completed.
To work around this issue, open & close Tray 3 or 4
when the message appears or upgrade the PCU
firmware to 04.01.G1 (or higher).
MX-DE13
MX-DE14
The MXDE13 or MXDE14 desk unit is
not recognised correctly (1 or 2
drawers missing from the
configuration) after installation.
To support future models, the Transfer Motor SB
installed on the MXDE13 & MXDE14 desk unit has been
changed since June 2013 production therefore, when
the current desk unit is installed onto an earlier
machine for example, both PCU & Desk firmware must
be upgraded to the latest version to ensure
compatibility.