SHARP
EEPROM HANDLING PROCEDURE
35
WARNING
:
Never execute Sim16 to clear U2 trouble WITHOUT investigating the root cause of U2 trouble by using
the following procedure:-
1.
Ensure to follow ESD procedures (using an earth strap) while handling the PWBs as EEPROM data
may become corrupted due to static charge.
2.
Never insert the EEPROM to the socket in reverse.
3.
U2 trouble occurs 100% if the machine is turned on after inserting the EEPROM in reverse.
Execution of Sim16 to clear this U2 trouble will lead to corrupted data which cannot be fully
recovered in the field.
4.
Make sure that PCU, MFP & SCAN EEPROMs are not switched - label each EEPROM for
identification purposes before removing from the PWB.
5.
Please handle EEPROMs with care to prevent bending or damage of pins.
They will be broken if bent several of times. (This type of trouble has been reported many times.).
6.
Do not use foamed styrol etc. for packing during the transportation of EEPROM.
Foamed styrol easily generates static charge. In some cases, EEPROM is damaged just by placing it
into foamed styrol.
7.
Make sure to use black sponge (anti-static) for packing during transportation. The black sponge is
also used to pack EEPROM provided as service parts.
CAUTION:
Please note that counter data and machine adjustment values are recorded in the EEPROM. If the data in
EEPROM is corrupted, it is impossible to recover. In such cases, the only solution will be to initialise the
EEPROM therefore, counter data and adjustment values will be reset to “0” or “default”. Once all the
adjustment values are set to default, it will be necessary to readjust all the adjustment values (ie. perform
a complete run-up procedure).
Caution to prevent damage on EEPROM:
In case any trouble other than U2 occurs to the machine and the PWB has been replaced (eg. remove and
reinstall the EEPROM onto the replacement PWB for example) and U2 trouble occurs right after power
on, never execute Sim16 under this condition.
As previously mentioned, the data in EEPROM will be corrupted after Sim 16 execution therefore:-
In such cases, EEPROM may have been inserted in reverse or MFP and PCU EEPROM may have
been switched.
Turn off the machine without execution of Sim16, install the correct EEPROM into the proper
position (on the PWB), power on the machine again and then execute Sim16. This way, U2 trouble
should be cleared.
Sim16 should only be executed to clear U2 trouble if it occurred without performing any repair or
maintenance as such.
As previously mentioned, execution of Sim16 won’t clear artificially-generated U2 errors. Instead, it may
actually damage the EEPROM, HDD storage and backup data.
Содержание MX-2640N
Страница 61: ...SHARP SENSOR LOCATION 61 MAIN ENGINE RSPF ...
Страница 62: ...SENSOR LOCATION SHARP 62 MX DE14 DESK MX DE20 DESK TANDEM DRAWER MX FN17 FINISHER ...
Страница 71: ...SHARP NOTES 71 Notes ...