![Sharp MX-2640N Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/sharp/mx-2640n/mx-2640n_technical-manual_365556067.webp)
SHARP
REPAIR HINTS
67
IMAGE SEND MODE
ALL
When using the Address Book
Forward function from Settings-Data
Backup menu via the Operation Panel,
the Address Book does not appear on
the target machine.
The Address Book Forward function is only supported
with models from the same model series:-
Examples:-
MX2640/3140/3640N to MX2640/3140/3640N = OK.
MX2640/3140/3640N to MXM365/465/565N = NG.
Please Wait message appears when
scanning multiple page jobs when
using the document feeder.
To prevent lines occurring due to optical contamination
when copying or scanning, shading correction is now
performed as default in-between each scan job (hence
Please Wait appears and the start button is greyed out
for a very short period).
However, you can disable this function (so that shading
correction is only performed at the beginning of the
Image Send or Copy mode) by changing following
setting
Sim 53-09 - Change Item B
(SIDEA SCAN POSITION ET_JOB) from 1 to 0.
How to scan to Office 365 email from
Sharp MFP?
Check the following settings under Network Settings ->
Service Settings -> SMTP
Primary Server: smtp.office365.com
Port Number: 587
Reply Email Address: ****@onmicrosoft.com
SSL: ON
SMTP Authentication: ON
User Name should be same as the Reply Email Address.
Note:
IMAP is not supported on the current Sharp
MFPs therefore only SMTP protocol can be used.
The correct port for SMTP with SSL enabled is 587 for
Office 365 email.
Scan to Email fails when using
hotmail.com or outlook.com
As Microsoft will not accept any email that is not
RFC5322 compliant, the sending email must have a
name and valid email address in the header therefore,
when configuring SMTP settings on the MFP, make sure
to add a Name & Email Address in the Default Send Set
menu (under System Settings\Image Send
Settings\Scan Settings).
Scan resolution is locked at 300dpi
When BK Letter Emphasis is ticked in the destination
settings of the Address Book or in the Scan Settings
under System Settings\Image Send Settings, the scan
resolution on the operation panel will be locked at
300dpi and cannot be changed.
Similar to the situation above, when using the PDF
compression kit and the scan file type is selected as
Compact PDF, the scan resolution will also be locked at
300dpi.
Содержание MX-2640N
Страница 61: ...SHARP SENSOR LOCATION 61 MAIN ENGINE RSPF ...
Страница 62: ...SENSOR LOCATION SHARP 62 MX DE14 DESK MX DE20 DESK TANDEM DRAWER MX FN17 FINISHER ...
Страница 71: ...SHARP NOTES 71 Notes ...