2-6
Setting the Operating and System Conditions
2
[4] Pattern display
Select "YES" or "NO" to determine whether to show the
pattern display (solid lines and dashed lines of the
rectangles in the window) over an image displayed on
the operation screen.
Note: When the "CAM1&2" is selected on the
"
MONITOR OUTPUT" (page 2-2), pattern
display cannot be selected.
Display examples
F C1 L
VX.X
(TYPE00)
OK
MEAS XXXXms
MEASURE 0 CAM1 POSI-DEVIATION
X0~6
Y0~7
READY
REGST. NO. 0(0~7)
X0=176.0
OK
Y0=322.0
OK
x0=+000.0
OK
y0=+000.0
OK
M0=+10000
OK
B0=+001.7
OK
X1=534.0
OK
Y1=480.0
OK
x1=+001.0
OK
y1=+001.0
OK
M1=+09999
OK
F C1 L
VX.X
(TYPE00)
OK
MEAS XXXXms
MEASURE 0 CAM1 POSI-DEVIATION
X0~6
Y0~7
READY
REGST. NO. 0(0~7)
X0=176.0
OK
Y0=322.0
OK
x0=+000.0
OK
y0=+000.0
OK
M0=+10000
OK
B0=+001.7
OK
X1=534.0
OK
Y1=480.0
OK
x1=+001.0
OK
y1=+001.0
OK
M1=+09999
OK
- When "YES" is selected for PATTERN DISPLAY.
-
When "NO" is selected for PATTERN DISPLAY
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
1
MONITOR OUTPUT
CAM1
2
CAPTURE IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY IMG
YES
6
SHOW
θ
FIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
NO
9
PC-MNTR
NO
0
THROUGH DISPLAY
NO
q
EXTENSION FUNC.
NO
TYPE RUN COND SCREEN SAVE
F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
YES
NO
YES
NO
PATTERN
DISPLAY
Description
Displays patterns in the window, such
as the rectangles defined for the
inspection area and the search area.
Patterns will not be displayed
on the operation screen.