16-16
Setting the Input/Output Conditions
16
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
■
Configuration example
Controller
Power supply (24 VDC)
Monitor
Camera 1 (image cap CCD trigger)
Camera 2 (image capturing)
Remote key pad
Data
CCD trigger
Work
Black White
Edge
Level
Measurement
Personal computer
Select one of
these.
■
Setting order
1
→
2
(
→
3
)
2
START CCD SAMPL
3
OUTPUT OBJ TYPE
PARALLEL
SERIAL
AUTO(EDGE)
AUTO(LEVEL)
PARALLEL
SERIAL
1
MEAS INP I/F
PSERIAL
TRIG CCD START
(10) Measurement start input = CCD trigger, start sampling = auto, object type change = general
purpose serial, result output = general purpose serial/parallel
The general purpose serial command (code 55
(H)
) is used to change the object type.