16-26
Setting the Input/Output Conditions
16
16-7 Setting the data output
When you communicate with the IV-S30J using a computer link or a serial communication interface
(general purpose serial IF) in the following conditions, perform steps (1) and (2) below to enable serial
output.
- Computer link: When outputting any data
Pages 18-
1
6.
- Communication interface (general purpose serial IF): When executing a measurement run command
4 (processing code 14
(H)
)
Pages 17-8 and 17-10.
[1] Select "ANY" for the serial output
Select "ANY" in the "
SERIAL OUTPUT" item on the "OBJECT TYPE I/O" menu.
Setting (operating) procedure
1. Select "MAIN COND" -> "OBJECT TYPE
COND" -> "TYPE00" -> "OBJ-TYPE I/O" in
that order.
2. The "OBJ-TYPE I/O" screen will appear. Move
the cursor to "
SERIAL OUTPUT" and press
the SET key. A popup menu will appear.
Select "ANY" and press the SET key.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM.CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
TYPE(NEW)
SELECT OBJECT TYPE COND
F C1 BRT
1
TRIG CCD START
2
CCD TRIG COND
3
SHUTTER SPEED
4
SERIAL OUTPUT
5
SET SERIAL BLOCK
6
CAM NO
7
CALIBRATION
8
CALIBRATION
F C1 BRT
OBJ-TYPE I/O SCREEN SAVE
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
1
TRIG CCD START
NO
2
SHUTTER SPEED
1/00060(1/30~1/10000)
3
SERIAL OUTPUT
ANY
4
CAM NO
1(1~2)
5
CALIBRATION
NO
ANY
BLOCK-ASSIGN