16-13
Setting the Input/Output Conditions
16
■
Configuration example
Camera 1 (image cap CCD trigger)
Camera 2 (image capturing)
Personal computer
Remote key pad
Sampling start,
object type change
Data
Controller
Power supply (24 VDC)
IV-S3
*
M
OUTPUT
INPUT
POWER
Y7
Y0
Y1
Y2
Y3
Y4
Y5
Y6
COM
COM
+
24V
X7
X0
X1
X2
X3
X4
X5
X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
■
Setting order
1
→
2
2
START CCD SAMPL
AUTO(EDGE)
AUTO(LEVEL)
PARALLEL
SERIAL
1
MEAS INP I/F
PSERIAL
TRIG CCD START
(8) Measurement start input = CCD trigger, start sampling, object type change = general purpose
serial, result output = general purpose serial/parallel
The CCD trigger is enabled after a measurement execution command is entered.
- See Chapter 17 for details about the measurement execution commands (codes 10, 11, 12 and
14
(H)
).
- When one of the measurement execution commands (codes 10, 11, 12 and 14
(H)
) is normally
received during sampling, the sampling will stop.
Note: When the settings listed in section "16-3 CCD trigger" have not been made, a "CCD TRIG
NOT SET. (error 34)" will occur.
■
Time chart
Note: Result output: The data in the block No., set in item "
SET SERIAL BLOCK" on the
"OBJ-TYPE I/O" screen, will be transmitted to the personal computer.
See page 16-
23.
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
Result
output
Result
output
Serial
Result output
Result output
CCD trigger
cycle
Start CCD
sampling by
turning ON
measurement
start input
READY signal is turned ON
at the conclusion
of the result output.
Stop CCD sampling
by measurement
command.
CCD trigger
window
(not highlighted)
Black
Black
White
Trigger
Trigger
Terminate
measurement
(C119)
Measurement result is valid at the
end of a measurement
PC calculation
condition
Parallel output
Halt PC operation
during measurement
Halt PC operation
during measurement
When the object type is changed,
all Y output and auxiliary relays
turn OFF.
Parallel output is valid for PC control after
the measurement result is determined.
Measurement
trigger
command
Measurement
trigger
command
Measurement
trigger
command
Measurement
trigger
command
READY output
(While measuring
or setting = L)