CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications
Applicable telephone line:
Public switched telephone network
Compatibility:
ITU-T (CCITT) G3 mode
Configuration:
Half-duplex, desktop transceiver
Memory size*:
512 KB (approx. 39 average pages
with no voice messages or OGMs re-
corded)
1 MB add-on available as option
Compression scheme:
MH, MR, MMR
Scanning method:
Flat-bed, solid-state CCD
Resolution:
Horizontal:
8 dots/mm
Vertical:
Standard: 3.85 lines/mm
Fine/Halftone: 7.7 lines/mm
Super fine: 15.4 lines/mm
Recording system:
Thermal transfer recording
Display:
7 x 5 dots, 1 line by 16-digit display
Reception modes:
FAX/TEL/ANS
Modem speed:
14400 bps with automatic fallback to
12000, 9600, 7200, 4800, or 2400
bps
Transmission time* :
Approx. 6 seconds (Memory trans-
mission)
Effective recording width:
203 mm (average)
Input document size:
Auto feeding:
Width: 148 to 216 mm
Length: 128 to 356 mm
Manual feeding:
Width: 148 to 216 mm
Length: 128 to 1000 mm
Effective scanning width:
210 mm max.
Automatic document feeder: 20 sheets max.
Halftone (gray scale):
64 levels (for photo transmission)
Contrast control:
Automatic/Dark selectable
Copy function:
Single/Multi-copy/Sort-copy (99 cop-
ies/page)
Telephone function:
Standard
(cannot be used if power fails)
Power requirements:
230 to 240 V AC, 50 Hz
Operating environment:
5 to 35
°
C, 20 to 80 % RH
Power consumption:
Stand-by: 11 W
Maximum: 110 W
Dimensions:
Width: 363 mm
Depth: 488 mm
Height: 188 mm (Without attach-
ments)
Weight:
Approx. 5.9kg
*
Based on ITU-T (CCITT) Test Chart #1 at standard resolution in
MMR (Memory Transmition), excluding time for protocol signals
(i.e., ITU-T phase C time only).
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for procduct
improvement without prior notice. The performance specifications figures indicated are nominal values of production units. There may be some
deviation from these values in individual units.
FO-1850TH
1 – 1
Содержание FO-1850
Страница 65: ...M E M O FO 1850TH 5 13 ...
Страница 73: ...Control PWB parts layout Top side 6 8 FO 1850TH ...
Страница 74: ...Control PWB parts layout Bottom side 6 9 FO 1850TH ...
Страница 76: ...TEL LIU PWB parts layout 6 11 FO 1850TH ...
Страница 78: ...6 13 Power supply PWB parts layout FO 1850TH ...
Страница 81: ...Operation panel PWB parts layout 6 16 FO 1850TH ...
Страница 83: ...Joint PWB parts layout 6 18 FO 1850TH ...
Страница 96: ...M E M O FO 1850TH 8 9 ...