3. 12. Entry data receive
This mode is used to receive the registered data which is sent from
the remote machine and to register the received data in the machine.
When this mode is used to receive the information, the remote ma-
chine must be set to the entry data send mode.
The information to be sent is as follows.
1. Telephone book data
2. Transmitter list
(The pass code is also printed on the polling type.)
3. Optional setting list
4. Soft switch list
5. Junk FAX number list
6. Timer reservation list
(for models in which timer communication is possible)
7. Pass code number
(only for models with polling function)
8. Program group information
3. 13. Flash memory check
Data is written into and read from the flash memory to check the data
conformity. When the unit enters this mode, the check is started.
3. 14. Flash memory clear
Data in the flash memory is cleared (memory clear). When the unit
enters this mode, the check is started.
* Operation of hardware and signal in the flash memory check mode
and flash memory clear mode, and the result of check
The result is announced by the buzzer beeps. The result of check is
printed.
Beeps
0
→
No error
1
→
Memory error
3. 15. RS232C check
The RS232C interface box is checked.
The result is printed after completion of check.
Press FUNCTION
9
8
7
START
START
Press FUNCTION key.
Press
key.
Press
key.
Bit1 - 8 are set.
Soft SW-A2 - SW-M2 are set.
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A2 = 0 0 0 0 0 0 0 0
S F T SW-M2 = 0 0 0 0 0 0 0 0
Press
key during setting.
To finish the settings halfway between
SW-A1 and SW-M2, press the STOP
key. In this case, the setting being done
to the SW No. on display will be nullified
while settings done to the preceding
SW Nos. remain in effect.
The soft switch mode is terminated.
S F T SW-A1 = 0 0 0 0 0 0 0 0
START
DATA No. 1 2 3 4 5 6 7 8
When the COPY key is pressed, the
contents of soft switches are printed.
4. How to make soft switch setting
To enter the soft switch mode, make the following key entries in
sequence.
FO-1850TH
2 – 4
Содержание FO-1850
Страница 65: ...M E M O FO 1850TH 5 13 ...
Страница 73: ...Control PWB parts layout Top side 6 8 FO 1850TH ...
Страница 74: ...Control PWB parts layout Bottom side 6 9 FO 1850TH ...
Страница 76: ...TEL LIU PWB parts layout 6 11 FO 1850TH ...
Страница 78: ...6 13 Power supply PWB parts layout FO 1850TH ...
Страница 81: ...Operation panel PWB parts layout 6 16 FO 1850TH ...
Страница 83: ...Joint PWB parts layout 6 18 FO 1850TH ...
Страница 96: ...M E M O FO 1850TH 8 9 ...