CHAPTER 5.
INSTALLATION INSTRUCTION
AY-XPC15PU
ITEMS
Q’ty
APPLICATION
ITEMS
Q’ty
APPLICATION
ITEMS
Q’ty
APPLICATION
1
Mounting plate
1
To mount the indoor
unit on the wall.
4
Dry battery
2
For the remote con-
trol.
AAA batteries.
7
Manuals
1
Operation manual
1
Installation manual
2
Long screw
5/32" x 39/32" L
(M4.5x30)
7
plate.
5
Short screw
3/16" x 13/16" L
(M4x20)
3
remote
control holder. (1)
8
Cable cover
1
To secure the cable
cable
cover. (2)
3
Remote control
1
To control remotely.
6
Remote control holder
1
To mount the remote
control on the wall.
[4].INSTALLATION DIAGRAM
[3].NOTES ON LOCATIONS
Provide as much installation space as possible for
[2].ACCESSORIES
[1].SAFETY PRECAUTIONS
| Installation must be made in accordance with the installation
manual by
service personnel.
| Be sure to use the attached accessories parts and
parts
for installation.
falling.
| The appliance shall be installed and wired in accordance with
national electrical code and by
personnel only.
| After installation has complete, check that there is no leakage of
refrigerant gas.
| Ventilate the room if refrigerant gas leaks during installation.
| Use the
electrical cable.
Make sure the cable is secured in place and that the terminals are free
result.
| Form the cable so that the control box cover, the cord holder and
cable holder are not loose.
OPER
INSTALL
1.
2. Make a drain hose hole that will allow easy condensate water drainage.
3.
both sides and above the unit.
4.
5. Keep TV set, radio and other similar appliances at least 1 m or more away from the unit and the remote control.
6. Keep the air inlet clear of obstacles that could block incoming air
7. The remote control may not function properly in a room equipped
lighting.
8. Select a location that does not cause loud operation noise and extreme vibrations.
| Tighten the
nut with a torque wrench according to the
method.
a long time and cause refrigerant gas leakage.
| When installing the unit, take care not to enter air substance other
than the
refrigerant(R410A) in the refrigerant cycle.
Otherwise, it can cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
| Be sure to connect the refrigerant pipe before running the compres-
sor.
Otherwise, it can cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
| Earth the unit.
Incomplete earth may cause electrical shock.
| Install an earth leakage breaker to avoid electric shock in case of
leak.
Use the current-activated, high-sensitivity, high-speed type breaker with a
rated sensitivity current of below 30 mA and an operating time of below 0.1
second.
| Arrange the drain hose to ensure smooth drainage.
|This room air conditioner uses refrigerant R410A.
Use refrigerant
.
Coating tape
(Commercially available)
2.4 inch (60 mm)
or more
2 inch (50 mm)
or more
2 inch (50 mm)
or more
Use the refrigerant pipes shown in the table below.
Pipe size
Pipe thickness
Thermal insulation
Liquid Side
1/4”(ø 6.35 mm)
0.03 in
(0.8 mm)
Thickness:
0.2 inch (6 mm) or thicker
Material:
Polyethylene foam
Gas Side
1/2"
(ø 12.7 mm)
The thermal insulation should cover both the gas and liquid pipes.