background image

12

Product Version 1.0 | Revision E | Released 2022-12-09

CONNECTING POWER

The power cable color coding is given in figure 6:
•  Connect the black wire to live
•  Connect the white wire to neutral (or phase 2 on 208V 
supplies)
•  Connect the green/yellow wire to ground (earth)

For a temporary outdoor installation the mains cable must be fitted with a grounded connector intended for exterior 
use. 
For permanent installations, a qualified electrician must wire the mains cable directly to a suitable branch circuit and 
as per local code. The junction’s ingress protection (IP) rating must be suitable for the location. Always use a junction 
box with a proper IP class suitable for the environment.
After connecting the fixture to power, run the on-board test by selecting the option “TEST→ SELFTEST” in the menu, 
to ensure that the fixture and each LED are functioning correctly. (POI versions are tested through RDM.)

PLEASE NOTE! THE PROTECTIVE CAPS MUST BE SECURELY MOUNTED ON ANY UNUSED CONNECTORS, IN OR-
DER TO MAINTAIN INGRESS PROTECTION (IP RATING).

CAUTION!

DO NOT CONNECT THE FIXTURE TO AN ELECTRICAL DIMMER SYSTEM, AS DOING SO MAY 

CAUSE DAMAGE

CONNECTING DATA

The fixture is controllable using a DMX control device, and it can be connected using either a DMX cable, or via the 
fixture’s built-in CRMX wireless receiver system.
When using a cabled DMX system, connect the DMX-In cable to the input connector and DMX-Out cable to the out-
put, both on the rear of the fixture’s base (chassis mounted male and female 5-pin XLR plugs). For outdoor installa-
tions, use only IP-rated XLR connectors suitable for outdoor use. Terminate the DMX out cable of the last fixture in the 
data link with a 120 ohm DMX termination. 
Note that SGM fixtures provide a passive DMX Thru signal as DMX Out, instead of an active output signal.

PLEASE NOTE! FOR POI VERSIONS, PLEASE REFER TO “INSTALLATION POI FIXTURE”

CONNECTING A WIRELESS TRANSMITTER

The fixture is designed to look for wireless transmitters in ‘connect’ state when this option is not yet enabled. The fix-
ture comes tested for wireless functionality from the factory, therefore the beginning of the pairing process is discon-
nect from the factory wireless DMX transceiver.
To connect the fixture to a wireless transmitter:

1.  Log off the currently paired wireless transmitter. Go to SETTINGS → WIRELESS DMX → LOG OFF in the menu. 

Fixture confirms logged off.

2. Press the connect button on the wireless transmitter.
3. Confirm that the fixture has paired with the wireless transmitter.

PLEASE NOTE! FOR POI VERSIONS, REFER TO “"WIRELESS DATA CONNECTION" ON PAGE 17”   .

SIGNAL PRIORITY

The fixture can be paired to an active wireless transmitter while also being connected to a cabled DMX signal. By de-
fault, the fixture will prioritize cabled DMX over wireless DMX. Through the Settings menu in the display or RDM, this 
can be changed so that the fixture will prioritize the wireless DMX signal over cabled DMX.
The active input type is displayed under the wireless signal strength indicator. The signal strength can be also checked 
via RDM data by using an external RDM device.

PLEASE NOTE! IN POI VERSION WITH WIRELESS, THE DMX SIGNAL STRENGTH IS CHECKED THROUGH RDM.

Color

Black

White

green/yellow

Conductor

live

neutral

ground (earth)

Symbol

or

L

N

Wire

 (L2)

Figure 6: Connecting AC Power/P-1 power cable 8 mm

Содержание P-6

Страница 1: ...USERMANUAL P 6 Product Version 1 0 Document Revision E Released 2022 12 09...

Страница 2: ...ect to change without notice SGM and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of...

Страница 3: ...3 Product Version 1 0 Revision E Released 2022 12 09 POI VERSION All dimensions in millimetres and inches Drawing not to scale DIMENSIONS...

Страница 4: ...3 INSTALLATION POI FIXTURE 13 Identification and terminology 14 Unpacking 14 Application considerations 14 Connecting temporary Power 15 Connecting temporary signal 16 Settings and Fixture Defaults 17...

Страница 5: ...NDALONE OPERATION 28 FIXTURE PROPERTIES 28 Factory default 28 LED Engine 28 Individual fixture settings 29 CONTROL MENU 31 RDM 31 Supported RDM functions 31 Sensors 32 ACCESSORIES 32 Filter frames 32...

Страница 6: ...from objects to be illuminated Install only in accordance with applicable building codes Ensure a minimum clearance of 0 3 m 12 in around the cooling fans Do not paint cover or modify the device and d...

Страница 7: ...with power and data cable leads are not intended for installation in permanently installed conduit or containment When installing luminaires in a permanent in stallation ensure cable leads are instal...

Страница 8: ...t to change without notice IDENTIFICATION AND TERMINOLOGY B A A 24 x RGBW LEDs B Tilt lock C Cooling fans D Control panel E OLED Display F Rubber feet G GORE TEX membrane H DMX in and out I Power in a...

Страница 9: ...e It has adequate ventilation It is not immersed or submerged in water TRANSPORT HANDLING Always use the supplied packaging or suitable flight case for transportation and storage Never carry the fixtu...

Страница 10: ...8 8 and a lock nut For longer term installations choose outdoor rated hardware 3 Align the omega bracket with the fixture base For standard Omega Bracket insert the fasteners into the fix ture base br...

Страница 11: ...t wing screws one on each side by turning them counter clockwise Tilt the fixture to the angle desired and hold it Lock the position by re tightening both tilt lock screws clock wise CAUTION ALWAYS LE...

Страница 12: ...ed XLR connectors suitable for outdoor use Terminate the DMX out cable of the last fixture in the data link with a 120 ohm DMX termination Note that SGM fixtures provide a passive DMX Thru signal as D...

Страница 13: ...vary from received products This is subject to change without notice A A 24 x RGBW LEDs B POI Tilt lock C Cooling fans D LED indicator E GORE TEX membrane F DMX in and out G Power in and out H Handle...

Страница 14: ...igned for use in outdoor installations This means that it is protected from Dust to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation High pressu...

Страница 15: ...roducts rdm addressing tool STEP 2 Connect the bare end data cable to the POI Up loader cable for POI fixtures STEP 3 Connect the USB up loader cable for POI fixtures to a computer with a USB Type A p...

Страница 16: ...fixture Look for the LED indicator to blink to confirm setting change DMX modes for POI and Std versions are identical Refer to CONFIGURING THE DEVICE later in this manual for specifics for more info...

Страница 17: ...ake sure the fixture is powered on be fore taking the following steps STEP 1 Using a SGM magnetic spanner tool place the magnet close to the LED indicator and wait for 3 seconds The LED indicator will...

Страница 18: ...ture The POI wash fixture may be installed in any orientation and it might take up to two brackets per fixture Depending on the structure please use appropriate and secure methods for mounting the Ome...

Страница 19: ...Countersunk Bolts Flat Bracket 8mm or smaller screw or bolt to structure 8mm or smaller screw or bolt to structure Fixture 13mm 0 5in hole diameter for attachment point M10 Stainless Steel Bolts POI O...

Страница 20: ...HE SLOT WITH 6 8 SERIES LABEL IS FACING AWAY FROM THE CENTER OF THE FIXTURE BOLTS TO MOUNTING SURFACE WILL USE THIS SLOT M10 Countersunk Bolts POI Universal Bracket Fixture Using a bolt through this s...

Страница 21: ...en to the surface Using the holes shown use appropriately rated fasteners for both location and surface material and construction Fasten ers should be no larger than M6 Use the supplied countersunk M1...

Страница 22: ...ig nose keys The fixture can be tilted in any orientation To adjust the tilt angle in POI fixtures Loosen the two tilt lock kobs one on each side by turning them counter clockwise using the small pig...

Страница 23: ...ut the SGM POI DMX cable For permanent installations have a qualified electrician wire the mains cable directly to a suitable branch circuit For a temporary installation the mains cable may be fitted...

Страница 24: ...ning on the fixture make sure the power cable is properly connected When the fixture is powered on it will boot and reset before displaying the selected operating mode and DMX start address Navigate t...

Страница 25: ...Operational mode B DMX address C External data indicator DMX D External data protocol next available DMX address Figure 20 Display EXTERNAL DATA PROTOCOL D Shows the external data protocol CRMX or DM...

Страница 26: ...ically Incorrect settings will result in unpredictable responses from the lighting controller Address sharing can be useful for diagnostic purposes and sym metrical control SET EDIT DMX ADDRESS The DM...

Страница 27: ...one pro grams can be defined and run from the menus and one of the pro grams can be set to run by default whenever the fixture is powered on Each of the three available standalone programs contains 24...

Страница 28: ...e fixture is installed hanging upside down it might be useful to flip the display so that it is easier to read To flip the display press ENTER and select SETTINGS FLIP DISPLAY or press the up and down...

Страница 29: ...cene 1 24 Red Red value in currently selected scene 0 255 Green Green value in currently selected scene 0 255 Blue Blue value in currently selected scene 0 255 Fade Time Min Fade in transition time to...

Страница 30: ...ay hardware revision Serial Number Display serial number RDM ID Display RDM ID Unique RDM ID for identification DMX View Display received DMX levels Sensors MAIN TEMP Displays fixture temperatures LED...

Страница 31: ...Sensor Definition 0x0201 GET SET Sensor Value 0x0080 GET Device Model Description 0x0400 GET SET Device Hours 0x0401 GET SET Lamp Hours 0x0051 GET Parameter Description 0x0501 GET SET Display Level 0x...

Страница 32: ...for P 6 Figure 25 8 way barndoor for P 6 The P 6 features various optional magnetic holographic filter frames Medium angle 19 Wide angle 45 Elliptical wide angle horizontal 63 x12 Elliptical wide ang...

Страница 33: ...date the fixture with the latest SGM firmware See below how to update the fixture with the latest firmware The SGM Uploader cable is also used for controlling the DMX val ues channel by channel throug...

Страница 34: ...click Upload Firmware The fixture will now update and reboot The Firmware Tool software offers a simple DMX controller featur ing 512 DMX channels for test purposes Figure 29 1 SGM Firmware tool Figu...

Страница 35: ...reless transmitter and connec tions DMX cables were disconnected Inspect DMX cables Fixture operates irregularly abnormally DMX cable polarization is inverted pin 2 3 Install a phase inverter or repla...

Страница 36: ...83060602 83061206 Omega bracket POI with M10 Screws BL WH P N 83060623 83060624 SGM USB uploader cable P N 83062011 SGM USB uploader cable POI P N 83062067 Filter frame Elliptical horz wide angle BL...

Страница 37: ...ht com Conforms to 2014 35 EU Low Voltage Directive Conforms to 2014 30 EU EMC Directive Conforms to 2011 65 EU RoHS2 Directive Conforms to ANSI UL Std 1573 Certified to CSA Std C22 2 No 166 Conforms...

Страница 38: ...38 Product Version 1 0 Revision E Released 2022 12 09 USER NOTES...

Страница 39: ...39 Product Version 1 0 Revision E Released 2022 12 09 SGM LIGHT A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: