17
Product Version 1.0 | Revision E | Released 2022-12-09
LED INDICATOR BEHAVIOUR
The fixture displays the status of connections, setting and errors through the LED indicator. It can have different colors
and three possible stages: static, flashing, or off.
Once configuration is complete, temporary power and data can be disconnected.
• Solid Orange: Fixture is starting up.
• Blinking Green: Wireless and/or wired DMX is connected and no errors.
• Solid Green: No wireless and/or wired DMX connection and no errors.
• Blinking Green-Orange: Error(s) have occurred and no wireless and/or wired DMX connection
• Solid Orange: Error(s) have occurred and wireless and/or wired DMX is connected.
• Blinking Orange : Hall sensor is activated. When activated more than 3 seconds wireless DMX connection is
logged off.
In POI fixtures with wireless, it is necessary to pair the fix-
ture with a new transmitter (by default, the fixture is
linked to the SGM factory transmitter during the testing
and QA process).
In order to do so, make sure the fixture is powered on be-
fore taking the following steps:
STEP 1: Using a SGM magnetic spanner tool, place the
magnet close to the LED indicator, and wait for 3 seconds.
The LED indicator will blink orange for 1-2 seconds, before
switching to static green again. The fixture can now be
paired to a new transmitter.
STEP 2: Select “connect” or “link” on a wireless DMX trans-
mitter. The transmitter and the internal SGM receiver
should now be linked together.
Repeat the process to link the fixture to another transmit-
ter.
To disconnect the fixture from the currently paired wireless transmitter, hold the magnet for 3 seconds over the LED
indicator. The LED indicator will blink orange for 1-2 seconds, switching later to green again. The fixture is now logged
off.
WIRELESS DATA CONNECTION
PLEASE NOTE! REMOTE DEVICE MANAGEMENT (RDM) REQUIRES A CORRECTLY INSTALLED AND TERMINATED
DMX CABLE.
When setting addresses through RDM and using USB dongles, it may be necessary to disable “USB selective sus-
pend”
to ensure a proper voltage to the DMX link. If any lag or trouble occurs when addressing, decrease the cable
length range to <12 m. and only address one fixture at a time.
Figure 11: POI Spanner