The G-1 Beam (POI) can operate on any 100–240 V, 50/60 Hz AC mains power supply.
Connect the a standard G-1 Beam to AC power by using the supplied cable with a powerCON TRUE1 connector, or similar with a
maximum of 20 A, to ensure the correct ingress protection (IP-rating).
The fixture must be grounded/earthed and be able to be isolated from AC power. The AC power supply must incorporate a fuse or
circuit breaker for fault protection.
The power cable color coding is given in figure 7:
•
Connect the black wire to live
•
Connect the white wire to neutral
•
Connect the green/yellow wire to ground (earth)
For a temporary outdoor installation the mains cable must be
fitted with a grounded connector intended for exterior use.
For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction’s
ingress protection (IP) rating must be suitable for the location. Always use a junction box with a proper IP class suitable for the
environment.
When installing standard type C circuit breakers there will be no limitations due to the fixture in-rush current. For assistance with
alternative configurations, contact your SGM representative.
After connecting the G-1 Beam to power, run the on-board test by selecting the option “TEST→ AUTOMATED TEST” in the menu, to
ensure that the fixture and each LED are functioning correctly.
POI versions have to be tested through RDM.
The standard G-1 Beam can also run on battery power (up to 12 hours, when three batteries are installed).
NB! Both DMX-in and DMX-out must be connected in order to maintain the IP65-rating.
The G-1 Beam without base or with ceiling mount bracket operates on 24V DC power with an external power supply. See “Installing
the ceiling mount bracket” on pages 17-18 for installation details.
NOTE: In POI versions is it supplied a fixed-chassis mounted with a bare-ended power cable. Connect the fixture to power
by mounting a power connector to the bare ended mains cable. Please refer to pages 25-26 for connecting AC power in POI
fixtures.
CAUTION!!
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
Connecting AC power
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
Figure 7: Connecting AC Power
Ceiling mount bracket (optional)
The G-1 Beam (POI) may also be installed with a ceiling mount bracket to be mounted directly to a surface. The ceiling mount bracket
also supports to be hung with an omega bracket.
The ceiling mount bracket is fitted directly to the head and offers a very low installation height. Since there is no base with power
connector, the fixture must be powered by an external PSU when using the ceiling mount. Power is supplied by an external 24V DC
power supply.
Please note: in POI versions is only possible to acquire the ceiling mount already mounted in the fixture, as the head is not
removable.
See on pages 17-18 how to install the ceiling mount bracket in standard fixtures.
Figure 6: Ceiling mount bracket
A: ISO View
B: Front view
C: Back view
D: Right side view
E: Top view