- 35 -
External Input Selection
Set Value
Input 1
Input 2
Input 3
Input 4
0 RUN STOP
TARE TARE
RESET
1
RUN/STOP
TARE/
TARE RESET
ZERO PRINT
●
2 RUN
STOP
SUB-TOTAL
3 ZERO TARE TARE
RESET
NET WEIGHT/
GROSS WEIGHT
F11
4 RUN STOP
ZERO
※
The Input signal pulse must be more than 1msec.
※
Under “F11-03” : NET weight / GROSS weight will be display on main display part, and if the
weight is Gross weight, “Gross” status lamp is “ON”. (This function will be activated under TARE
setting mode)
“STEADY” condition check time setting
F12 03
0
∫
20
During the set time period, estimate weighing part’s “STEADY”
condition and display.
If you set small value, indicator will take “STEADY” fast, if you set
large value, indicator will take “STEADY” slow.
※
Within “Motion Band Range” and “Zero Tracking Compensation Range”, weight variation is not
over/under the range during “STEADY” condition check time period(F12), indicator will take
“STEADY” and “STEADY” lamp is “ON”.
STEADY Break point
F12-03
F12-06
“STEADY” check period
Weight
In case of “F12-03”, the weight variation is not exceed motion Band
and Zero tracking range within set time period, indicator will take
Steady. But, if you change the setting to “F12-06” there is one
breaking point, the indicator will not take Steady.