- 18 -
5. SET-UP
5-1. Calibration
Adjust weight balance between “Real weight” on the load cell(Weight Part) and “Displayed weight of
Indicator”. When you replace LOAD CELL or Indicator, you have to do Calibration process once again
5-2. Test Weight Calibration Mode (Using Test weight)
Prepare At least 10% of Max. capacity of your weighing scale, and remove
“CAL-BOLT”
on the Front
panel and press
“CAL - LOCK S/W”
inside.
Then, you can enter the Calibration Mode with
and start calibration mode with
pressing
key.
Remove the CAL.Bolt.
Push the CAL. S/W
Check the “SET-CAL.
Massage on display.
※
For the save the each step, press
key, for the cancel or move back, press
key.
Step No.1 - Setting “Capacity of weighing Scale”.
Set Max. Capacity of Load cell
Press “Enter” and move the next step.
Under this step, input Max. Capacity of you weighing scale.
Input Max. capacity of your weighing scale with No. keys.
The Max. capacity can not be exceed Max. capacity of load cell.
After finishing input, press
key and save and move to next step.
Step No.2 - Setting “Decimal Point”
SeT-CAL