- 43 -
Weighing Mode 4. Loss
◆
-in Weight Mode 2 - No Finish/Error Relay output
1. Set value setting
FINAL(Discharge Target), PRE 1(Feeding Target), PRE 2(Bulk Discharge), FREE FALL(Drib Discharge)
Setting conditions : (PRE 1
≥
FINAL), (FINAL - Free Fall > PRE 2)
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Automatic Free Fall Compensation Function available : F-Function 20
3. Low / High output (LOW/HIGH value must be smaller than Max. Capacity.)
Under relay output : Relay output, when the current weight is less than (FINAL-LOW) value.
Over relay output : Relay output, when the current weight is more than (FINAL-HIGH) value.
4. Weighing Start : Tare key input
Æ
weighing start, After Finish
Æ
automatic TARE RESET
5. Manual Discharge : If the remained material is under “F29 set range”, you can discharge with
“F+RUN/STOP” key input.
6. Relay Output
Relay
Contents
Relay
Contents
PRE1
Current weight =PRE 1(ON)
Under “F29 set range”(OFF)
Low
Current weight < FINAL-LOW
(ON)
PRE2
Current weight=PRE 2(ON)
After Finish(OFF)
High
Current weight > FINAL-HIGH
(ON)
FINAL
Current weight=FINAL(ON)
After Finish(OFF)
Near Zero
Within “EMPTY range”(ON)
※
This Flow chart was made based on
“LOW/HIGH” set value is “0
PRE 1
Weight
Near Zero
TARE input
PRE 1
PRE 2
FINAL
LOW
HIGH
Near Zero
TARE reset
PRE 2
FALL
START
FINAL
FINAL Set
Output1
Output2
Output3
Output4
Output5
Output6