6
Electrical Installation
HanModular® ABOX "MTA...-H12.-...-00" and "MTA...-H22.-...-00"
Operating Instructions – MOVIFIT
®
SC
67
6.5.2
Assignment of power bus plug connector X1
The following figure depicts the X1 power bus plug connector (HanModular
®
with
2 module pin elements, male):
60486AXX
X1 power bus plug connector
Module
Pin
Assignment
Module a
Han CC protected
a.1
Mains phase L1
a.2
Mains phase L2
a.3
Mains phase L3
a.4
n.c.
Module b
Han EE
b.1
+24V-C
b.2
n.c.
b.3
n.c.
b.4
+24V-S
b.5
0V24-C
b.6
n.c.
b.7
n.c.
b.8
0V24-S
Grounding pins
PE
PE / housing
8
4
7
3
5
2
1
1
2
3
4
6
b
a
DANGER
The maintenance switch only disconnects the integrated motor circuit breaker from the
mains. Voltage is still present on the plug connector X1 of the MOVIFIT
®
.
Severe or fatal injuries from electric shock.
• Switch off the power to the MOVIFIT
®
using a suitable external disconnecting
device before touching the plug connector contacts.