7
Startup
Startup instructions
94
Operating Instructions – MOVIFIT
®
SC
7.1.3
Wiring notes for brakes
• If SEW motors with brakes are used, the brake can be connected to the terminals
provided in MOVIFIT
®
for the SEW brake without any further measures (do not use
a brake rectifier).
• Two digital outputs on MOVIFIT
®
are available for operating non-SEW motors with a
brake. These outputs can be used to control non-SEW brake(s) using appropriate
additional measures (e.g. brake rectifier).
7.1.4
Possible MOVIFIT
®
motor combinations
MOVIFIT
®
SC is available in the unit power ratings 1.5 kW and 4 kW. The unit is
equipped with an overcurrent protection device that is designed for the corresponding
unit power and triggers at 180% of the rated unit current.
DANGER
If the binary outputs DB00 or DB01 are used to control the brake, do not change the
parameters of the functions of the binary outputs.
Severe or fatal injuries.
• Before using the binary output for controlling the brake, check the parameter
settings.
STOP!
To ensure that this overcurrent protection device does not trigger, you must strictly
comply with a total current of 4 A (1.5 kW unit) or 8.7 A (4 kW unit), in accordance with
the operating mode and the motor(s) used.