9
Technical data
Hybrid cable type "B" and "B/2,5"
Operating Instructions – MOVIFIT
®
MC
155
• Operating voltage for 0.75 mm
2
conduc-
tor:
Max. 600 V
according to
Max. 600 V
according to
• Insulation resistance at 20° C:
Min. 20 MΩ x km
Min. 20 MΩ x km
9.7.3
Mechanical properties
• Suitable for cable carriers
– Bending cycles > 2.5 million
– Travel speed ≤ 3 m/s
• Bending radius
in the cable carrier:
for fixed installation:
10 x diameter
5 x diameter
• Torsional strength (e.g. rotary table applications)
– Torsion ± 180° for a cable length of > 1 m
– Torsional cycles > 100 000
INFORMATION
You will have to check the mechanical marginal conditions if you encounter reversed
bending and high torsional load for a length of < 3 m. Please contact
SEW
‑
EURODRIVE in such cases.
9.7.4
Thermal properties
• Processing and operation:
-30 to +90 °C (current-carrying capacity according to
DIN VDE 0298-4)
-30 to +80 °C according to
• Transport and storage:
-40 to +90 °C (current-carrying capacity according to
DIN VDE 0298-4)
-30 to +80 °C according to
• Flame-retardant according to UL1581 Vertical Wiring Flame Test (VW-1)
• Flame-retardant according to CSA C22.2 Vertical Flame Test (FT-1)
9.7.5
Chemical properties
Cable type
B
B/2,5
• Oil resistant:
In accordance with
VDE 0472
part 803, method B
In accordance with
VDE 0282
part 10 HD 22.10 S1
• General fuel resistance (such as diesel, gasoline)
according to DIN ISO 6722 parts 1 and 2
• General resistance to acids, alkalis, cleaning agents
• General resistance against dusts (e.g. bauxite, magnesite)
19484828/EN – 01/2015