5
Electrical installation
Hybrid cables
Operating Instructions – MOVIFIT
®
MC
108
MOVIFIT
®
MC terminal
Hybrid cable
MOVIMOT
®
1
MOVIMOT
®
2
MOVIMOT
®
3
Wire color/label
X7/1
X8/1
X9/1
Green-yellow
X7/2
X8/2
X9/2
Black/L1
X7/3
X8/3
X9/3
Black/L2
X7/4
X8/4
X9/4
Black/L3
X71/1
X81/1
X91/1
White / 0 V
X71/2
X81/2
X91/2
Green/RS-
X71/3
X81/3
X91/3
Orange/RS+
X71/4
X81/4
X91/4
White / 0 V
X71/5
X81/5
X91/5
Red / 24 V
The inner shields (2x) are connected via shield
plates in the MOVIFIT
®
ABOX; see the chapter
"Connecting MOVIMOT
®
Shield end
Note the enabled direction of rotation
Check to see if the required direction of rotation has been enabled on MOVIMOT
®
.
R
X6: 11,12
L
X6: 9,10
24V X6: 1,2,3
Both directions of rotation
are enabled.
R
X6: 11,12
L
X6: 9,10
24V X6: 1,2,3
Only CCW direction of rota-
tion is enabled.
Setpoint selections for CW
direction of rotation cause
the drive to stop.
R
X6: 11,12
L
X6: 9,10
24V X6: 1,2,3
Only CW direction of rota-
tion is enabled.
Setpoint selections for
CCW direction of rotation
cause the drive to stop.
R
X6: 11,12
L
X6: 9,10
24V X6: 1,2,3
Drive is blocked or brought
to a stop.
19484828/EN – 01/2015