![SEW movifit mc Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/sew/movifit-mc/movifit-mc_operating-instructions-manual_1249995142.webp)
7
Operation
MOVIFIT® MC status LEDs
Operating Instructions – MOVIFIT
®
MC
142
"F-STATE" LED
The following table shows the statuses of the "F-STATE" LED:
LED
Meaning
Measure
Off
The S12 safety option is currently in the
initialization phase.
S12 safety option is not available.
Verification is not completed (by switch-
off/on or by bus startup)
• Check configuration of bus
master.
• Switch the unit off/on.
Yellow
Illuminated
S12 safety option is in RUN mode, but
safety parameters not verified yet.
• Perform verification of
safety parameters.
Yellow
Flashing
Flash code for identification of the de-
vice during authentication (entering the
serial number in "Assist S12")
Green
Illuminated
S12 safety option is in RUN mode, veri-
fication of safety parameters completed.
-
Yellow/
green
Flashing
Test mode for drive safety functions is
active.
-
Red
Flashing
Error occurred
(error can be acknowledged).
• Error diagnostics.
• Correct the error and ac-
knowledge via F host or
programmed F-DI input.
Red
Illuminated
An error has occurred.
(Error cannot be acknowledged)
No 24 V_0 supply voltage
• Error diagnostics
• Check voltage supply.
19484828/EN – 01/2015