6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
81
Device power
Coding of the connections
11 kW
a
c
1
5
6
2
8
4
7
3
15 kW
a
c
1
5
6
2
8
4
7
3
22 kW
a
c
1
5
6
2
8
4
7
3
DC 24 V supply
The internal components can be supplied with DC 24 V either from the device or via
an external DC 24 V backup voltage.
To use the
internal
DC 24 V supply, you must jumper the following contacts:
•
[c].1 and [c].3
•
[c].5 and [c].7
INFORMATION
If you use an external DC 24 V backup voltage, do not connect contacts [c].3 and
[c].7.
To use an
external
DC 24 V backup voltage, connect it to the following contacts:
•
[c].1
•
[c].5
26596598/EN – 10/2020