Startup
Disconnecting the CAN bus
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
148
7.3.2
Loading the user program
ü
IP address MNC45A controller: 192.168.10.4
ü
Subnet mask: 255.255.255.0
1. Establish a connection to the device. Use the Wi-Fi infrastructure or connect the
device using the X4223 connection.
2. Load the user program onto the MNC45A controller as shown in the following fig-
ure. For further information on software management, refer to the following docu-
mentation: "Parameterizable Plant Software MOVIVISION
®
Parameter and Diag-
nostics Tool" manual.
9007230762925067
7.3.3
Additional information
For further information, refer to the following documentation:
•
"Parameterizable Plant Software MOVIVISION
®
Parameter and Diagnostics Tool"
manual.
•
"Parameterizable Plant Software MOVIVISION
®
– MOVIPRO
®
Software Interface"
manual.
•
"MOVIDRIVE
®
MDX60B/61B" system manual
7.4
Disconnecting the CAN bus
The internal CAN bus of the device is routed out of the device at the terminals
X4101_... This means the bus cannot be terminated inside the device.
ü
CAN terminating resistor 13287036
1. Disconnect the CAN bus at the last station.
2. If the device itself is the last station, disconnect the CAN bus at the X4101_.. con-
nection with the CAN terminating resistor.
26596598/EN – 10/2020