6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
73
6.12.4
X1213: AC 400 V input/DC 24 V supply for interface box
Function
•
AC 400 V input to supply units up to 22 kW
•
DC 24 V output and input
•
Signal contact for external maintenance switch
•
For connecting an interface box (PZM)
Connection type
Han-Modular
®
10 B, male
Connection diagram
c
a
8
1
2
1
5
6
2
1
5
6
2
4
7
3
8
4
7
3
3
[a] Han
®
C module, male
No.
Name
Function
1
L1
Supply system phase 1
2
L2
Supply system phase 2
3
L3
Supply system phase 3
[b] Han
®
EE module, male
Coding of the device power, see chapter "Coding" (→
[c] Han
®
EE module, male
No.
Name
Function
1
+24V_C
DC 24 V input – backup voltage
2
SC
Signal contact for maintenance switch
3
VO24
DC 24 V output
4
n.c.
Not connected
5
0V24_C
0V24 reference potential – backup voltage
6
n.c.
Not connected
7
GND
Reference potential
8
n.c.
Not connected
26596598/EN – 10/2020