6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Description of the control elements
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
37
6.2.4
DIP switches S1 and S2
NOTICE
Damage to the DIP switches caused by unsuitable tools.
Damage to the DIP switches.
• To set the DIP switches, use only suitable tools, such as a slotted screwdriver
with a blade width of no more than 3 mm.
• The force used for setting the DIP switches must not exceed 5 N.
S2
S2
S1
9007199881389579
DIP switch S1:
S1
1
2
3
4
5
6
7
8
Meaning
Binary coding
RS485 unit address
Motor
protection
Motor
performance
level
PWM
frequency
No load
damping
2
0
2
1
2
2
2
3
ON
1
1
1
1
Off
Motor
one stage smaller
Variable
(16, 8, 4 kHz)
On
OFF
0
0
0
0
On
Motor
adjusted
4 kHz
Off
DIP switch S2:
S2
1
2
3
4
5
6
7
8
Meaning
Brake type
Brake released
without enable
Operating
mode
Speed moni-
toring
Binary encoding
additional functions
2
0
2
1
2
2
2
3
ON
Optional brake
On
V/f
On
1
1
1
1
OFF
Standard brake
Off
VFC
Off
0
0
0
0
21328994/EN – 11/2014