Commissioning
88
Commissioning
21
258
_10
0300
06/EN - 0
3/2
022
Operating manual [27779289/EN] - MAXO-RG single-axis controls
21.2.2
Connections
NOTICE
Danger from open connections
Destruction or damage of the control as well as malfunctions
•
All unused connections must be closed with suitable blind covers.
-> Preserving the control protection class
-> Protecting connections from dirt
-> Protecting against short circuits (when water penetrates)
•
Make sure the plugs and blind covers have a corresponding IP class (EN 60529).
Installation: Connector panel
•
Connect plug contacts according to EPLAN or specifications in these instructions
Installation: Harting connection
•
Connect the plug to the controller's X2 connection.
•
Lock the plug contact -> flip the connection lever until it engages
Installation: M12 connections (flange)
(Description applies to all controller M12 connections)
•
Plug in M12 plug or M12 blind termination and screw down.
•
Tightening torque:
0.6 Nm