Software - configuration & parameterizing
80
Software - configuration & parameterizing
20
258
_10
0300
06/EN - 0
3/2
022
Operating manual [27779289/EN] - MAXO-RG single-axis controls
20.4.8
Parameter: Status links
Up to 10 different configurations can be created here. Depending on different IO config-
urations, several status messages can be generated by using the status links.
* No entry “-” means that no entry has to be made.
** No entry “-” means that the value 0 is used (connection until OUT1).
Parameter
Selection
Description
E1 ... E7
-/0/1*
0 ... Input is queried for LOW
1 ... Input is queried for HIGH
If no entry is made, then the input status is irrel-
evant for this link.
ON/OFF
-/0/1*
PCM
-/0 ... 255*
PCM command can be selected; if nothing is en-
tered, the PCM command is irrelevant for this
link.
Speed con-
trol
-/0/1*
0 ... Query for speed control inactive
1 ... Query for speed control active
If nothing is entered, the speed control status is
irrelevant for this link.
Anti-valence -/0/1*
Anti-valence test
Item
-/0/1*
Positioning: 0 ... inactive, 1 ... active
Error active
-/0/1*
0 ... Query for fault inactive
1 ... Query for fault active
If no entry is made, the input status is irrelevant
for this link.
Connection
-/0/1**
Status link: 0 ... not active, 1 ... active
RM
-/0/ 1 ... 3**
Feedback: 1 ... 3 Number of the feedback signal
(see “error links”)
Error
-/0/1**
Error: 1 ... Error message is generated
Hold reset
-/0/1**
1 ... Reset holding function (see “IO links”)
OUT1
-/0/1**
1 ... Digital output is switched
OUT2
-/0/1**
1 ... Digital output is switched
OUT1 mode -/0/1**
0 ... Digital output is switched
1 ... Digital output flashes every second
OUT2 mode -/0/1**
0 ... Digital output is switched
1 ... Digital output flashes every second
Delays
Delay status
link 1 ... 10
0 ... 65000ms
Deceleration time after which the parametrized
status message (1 ... 10) occurs