75
Software - configuration & parameterizing
Software - configuration & parameterizing
20
Operating manual [27779289/EN] - MAXO-RG single-axis controls
258
_10
0300
06/EN - 0
3/2
022
20.4.4
Parameter: Stop sensor
Parameter
Selection
Description
Stop sensor
Check box
Activate if a stop sensor is used (e.g. Senso-
Part)
Fast switch
of distance
0 ... 10000mm
The drive is stopped if the measured distance is
smaller than the adjusted value.
Near range
distance
0 ... 10000mm
Distance in the near range
Far range
distance
0 ... 10000mm
Stop distance in the far range
Remaining
distance in
buffer speed
before reach-
ing the stop
position
0 ... 1000mm
Distance after which the buffer speed is used.
Buffer speed 0 ... 1200Hz/10
Buffer speed
Limiting dis-
tance after
identifying an
object
0 ... 20000mm
Distance after which the speed limitation is ac-
tive.
Speed limita-
tion after
reaching the
limit distance
0 ... 120Hz
Maximum driving speed for active speed limita-
tion.
Deceleration
ramp speed
limitation af-
ter reaching
the limit dis-
tance
0 ... 255 Hz/s
-
Delay colli-
sion protec-
tion function
near range
0 ... 255 Hz/s
Deceleration ramp collision protection in near
range
Deceleration
collision pro-
tection func-
tion far range
0 ... 255 Hz/s
Deceleration ramp collision protection in far
range
Restart the
delay after
exceeding
the restart-
ing hystere-
sis
0 ... 65000ms
Restart delay time
Restart hys-
teresis
0 ... 20000mm
Restart hysteresis