6
Operation
Manual mode
Operating Instructions – MOVI4R-U
®
Frequency Inverter Module
25
Status LED
Meaning
Red
A fault has occurred. The inverter is not ready for operation.
See chapter "Fault list".
6.3
Manual mode
In manual mode, you control inverter enable and specify the direction of rotation as
well as speed solely using the control knob.
1. Connect the voltage supply.
2. Select function menu 10 "Manual mode" from the selection menu, and briefly press
the control knob.
DI03
Boost
n
n
max
n
x
2
N
P
Ι
U
N
8900038283
ð
Manual mode is now active.
ð
LEDs 1 and 10 are lit up.
ð
The drive is not enabled.
DI03
Boost
n
n
max
n
x
2
N
P
Ι
U
N
8900064011
3. When you turn the control knob to the right, you enable clockwise rotation and in-
crease the speed setpoint up to n
max
. When you then turn the control knob to the
left again, you decrease the speed setpoint up to 0.
DI03
Boost
n
n
max
n
x
2
N
P
Ι
U
N
8896140683
28520688/EN – 12/2018