4
Installation
Electrical connections
Operating Instructions – MOVI4R-U
®
Frequency Inverter Module
16
You can set the digital input signals DI 01 through DI 03 using switches [1] to [3]
(latching to the left/spring-return to the right). Instead, you can connect the digital input
signals via the 4 mm terminals. In this case, observe the technical specification of the
frequency inverter.
4.2.4
X2: Analog inputs/outputs
X2
COM
X2:1
COM
X2:5
AO REF 10V
X2:2
AOUT
X2:4
AIN
X2:3
15172524043
COM
X2.1: Reference potential/mass
AIN
X2.3: Analog input, 0 to 10 V
COM
X2.5: Reference potential/mass
AO REF 10V
X2.2: +10 V output
AOUT
X2.4: Analog output 0 to 10 V
4.2.5
X3: Motor connection
U
V
W
X3
15172094987
Connect the motor at the 4 mm terminals of the motor phases U, V and W.