OPERATION
UNIT INSPECTION
Thoroughly inspect the unit upon delivery. Immediately report any damage that occurred during transportation to the
delivery carrier. Request a written inspection report from a claims inspector to document any necessary claim.
ICE STORAGE AND DISPENSING
Servend dispensers are designed to dispense hard, cube ice up to one-inch square. The ice shapes and sizes listed
below are recommended for dispensing.
Warm “Super Cooled” Ice Before Dispensing
“Super Cooled” ice is not
recommended for dispensing. “Super cooled” ice is ice that has been stored in freezers below 32
o
F. Should it be
necessary to temporarily use “super cooled” ice, allow the ice to warm at room temperature for 25 to 30 minutes before
placing the ice in the dispenser.
Dispensing compressed flake “nugget” ice in Servend dispensers takes special handling. Most dispensers require
special bin components plus a universal ice management kit. Contact MBE regarding details for your particular
installation.
ROCKING CHUTE ICE DISPENSING
COLD PLATE BEVERAGE COOLING
A cold plate is a block of aluminum with serpentine stain-
less steel tubes molded inside the aluminum block. The
cold plate is approximately the same length and width
as the bottom of the dispenser bin. Ice sits on top of the
cold plate and cools the cold plate. The stainless steel
tubes inside the cold plate carry carbonated water (soda
water), noncarbonated water (plain water) and syrup to
the beverage valves. While flowing through the stainless
steel tubes in the cold plate, water and syrup are chilled
to serving temperature.
BEVERAGE VALVES
Post-mix beverage valves are designed to precisely meter the flow of both water and syrup to obtain the proper mixing
ratio. The syrup and soda water components of the post-mix beverage are mixed as they leave the beverage valve.
As the customer presses the rocking chute, the arm at
the top left rear of the chute pushes upward on the door
lock. The door opens until it contacts the stops in the
mounting brackets. The plastic arm on the ice chute also
activates the lever of the ice dispensing switch. When ac-
tivated, the micro switch starts the gear motor. The gear
motor turns the paddle wheel and agitator arm. The paddle
wheel carries ice. Periodic agitation is optional on the MD-
150 and MD-175 and is standard on the MD-200, MD-250,
MD-302 and MD-402. During periodic agitation, the paddle
wheel and agitator turn for approximately three seconds
every three and one half-hours. The door lock prevents ice
from being dispensed during the agitation cycle.
(See Also
Sequence of Operation
)
Содержание MD 150
Страница 12: ...12 INSTALLATION COLD CARB BAG IN BOX B I B SYSTEM ...
Страница 16: ...16 INSTALLATION MD 150 6 VALVE PLUMBING DIAGRAM MD 150 6 VALVE FLEX MANIFOLD ...
Страница 17: ...Installation and Service Manual 17 INSTALLATION MD 175 8 VALVE PLUMBING DIAGRAM MD 175 8 VALVE FLEX MANIFOLD ...
Страница 18: ...18 INSTALLATION MD 200 250 8 VALVE PLUMBING DIAGRAM MD 200 250 8 VALVE FLEX MANIFOLD ...
Страница 20: ...20 INSTALLATION MD 302 12 VALVE PLUMBING DIAGRAM LEFT RIGHT MD 302 12 VALVE FLEX MANIFOLD 1 PER SIDE ...
Страница 22: ...22 INSTALLATION MD 402 20 VALVE PLUMBING DIAGRAMS MD 402 20 VALVE FLEX MANIFOLD 1 PER SIDE LEFT RIGHT ...
Страница 42: ...42 EXPLODED VIEWS PARTS DIAGRAMS MD 150 175 200 250 EXPLODED VIEW ...
Страница 43: ...Installation and Service Manual 43 EXPLODED VIEWS PARTS DIAGRAMS MD 150 PARTS LIST MD 175 PARTS LIST ...
Страница 44: ...44 EXPLODED VIEWS PARTS DIAGRAMS MD 200 250 PARTS LIST ...
Страница 45: ...Installation and Service Manual 45 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 402 EXPLODED VIEW ...
Страница 46: ...46 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 PARTS LIST MDH 402 PARTS LIST ...
Страница 55: ...Installation and Service Manual 55 EXPLODED VIEWS PARTS DIAGRAMS MDH 402 115V WIRING DIAGRAM ...
Страница 61: ......
Страница 62: ...Installation and Service Manual ...