Installation and Service Manual
31
OPERATION
MDH SERIES SPECIFICATIONS
MDH Series dispensers have a stainless steel cabinet and lighted merchandiser standard. Beverage valves, coldplate
connections, drain connections and electrical components are front serviceable. MDH Series dispensers drain
through a two
3
/
4
" NPT connection to the drain pan. The standard voltage for MDH Series dispensers is 120VAC-
60Hz. A power cord is provided with 120VAC-60Hz models only.
MDH Series dispensers are available in the following optional voltages:
•
100VAC-50/60Hz
•
220VAC-50Hz
•
220VAC-60Hz
MDH Series dispensers use two
1
/
7
hp gearmotor. Optimum ambient conditions for MDH Series dispensers are
between 50
0
F and 95
0
F.
MDH-302
MDH-302 w/EM
MDH-402
MDH-402 w/24" EM
MDH-402 w/34" EM
DimensionsW
x D x H
42 ¾"" x 30 1/2" x 33"
42 ¾" x 30 ½" x 44" 60" x 30 ½" x 32" 60" x 30 ½" x 44"
60" x 30 ½" x 54"
Ice Storage
300 lbs
300 lbs
400 lbs
400 lbs
400 lbs
Beverage
Valves
10 or 12
10 or 12
16 or 20
16 or 20
16 or 20
Coldplate
Two (2) 9 circuit
3-2-1 manifold
Two (2) 9 circuit
3-2-1 manifold
16 valve: Two (2)
12 circuit
3-1-1-3 manifold
20 valve: Two (2)
15 circuit
3-1-2-1-3
manifold
16 valve: Two (2)
12 circuit
3-1-1-3 manifold
20 valve: Two (2)
15 circuit
3-1-2-1-3 manifold
16 valve: Two (2)
12 circuit
3-1-1-3 manifold
20 valve: Two (2)
15 circuit
3-1-2-1-3 manifold
Amperage
3.5 FLA
4.0 FLA
4.5 FLA
4.5 FLA
5.0 FLA
Agitation Timer
Standard
Standard
Standard
Standard
Standard
Shipping
Weight
430 lbs
490 lbs
615 lbs
715 lbs
715 lbs
Содержание MD 150
Страница 12: ...12 INSTALLATION COLD CARB BAG IN BOX B I B SYSTEM ...
Страница 16: ...16 INSTALLATION MD 150 6 VALVE PLUMBING DIAGRAM MD 150 6 VALVE FLEX MANIFOLD ...
Страница 17: ...Installation and Service Manual 17 INSTALLATION MD 175 8 VALVE PLUMBING DIAGRAM MD 175 8 VALVE FLEX MANIFOLD ...
Страница 18: ...18 INSTALLATION MD 200 250 8 VALVE PLUMBING DIAGRAM MD 200 250 8 VALVE FLEX MANIFOLD ...
Страница 20: ...20 INSTALLATION MD 302 12 VALVE PLUMBING DIAGRAM LEFT RIGHT MD 302 12 VALVE FLEX MANIFOLD 1 PER SIDE ...
Страница 22: ...22 INSTALLATION MD 402 20 VALVE PLUMBING DIAGRAMS MD 402 20 VALVE FLEX MANIFOLD 1 PER SIDE LEFT RIGHT ...
Страница 42: ...42 EXPLODED VIEWS PARTS DIAGRAMS MD 150 175 200 250 EXPLODED VIEW ...
Страница 43: ...Installation and Service Manual 43 EXPLODED VIEWS PARTS DIAGRAMS MD 150 PARTS LIST MD 175 PARTS LIST ...
Страница 44: ...44 EXPLODED VIEWS PARTS DIAGRAMS MD 200 250 PARTS LIST ...
Страница 45: ...Installation and Service Manual 45 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 402 EXPLODED VIEW ...
Страница 46: ...46 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 PARTS LIST MDH 402 PARTS LIST ...
Страница 55: ...Installation and Service Manual 55 EXPLODED VIEWS PARTS DIAGRAMS MDH 402 115V WIRING DIAGRAM ...
Страница 61: ......
Страница 62: ...Installation and Service Manual ...