Installation and Service Manual
13
1
Location
- Avoid placing the dispenser and/or ice
machine near heat sources such as radiators, ov-
ens, refrigeration equipment and direct sunlight.
2
Clearances
- Six inch (15.2 cm) clearance on all
sides of the icemaker is needed.
3
Front of icemaker to be flush with front of dis-
penser
- The front of the icemaker should be flush
with the front of the dispenser, as shown in the draw-
ing above. Because the icemaker is flush with the
front of the dispenser, some icemakers may over-
hang at the back of the dispenser.
4
Drains
- A separate drain line is required for the ice
machine, in addition to a drain line for the ice/bev-
erage dispenser.
5
MD Series dispensers require an adapter kit to
install a top-mounted icemaker.
Contact your lo-
cal Servend distributor for the correct adapter kit.
INSTALLATION
TOP MOUNTED ICEMAKER REQUIREMENTS
NOTE: For full information about icemaker installation, including plumbing lines connections and
electrical requirements, see the icemaker installation manual.
ICE FLOW RESTRICTOR
Ice Flow Restrictor
For all Servend MD/MDH Series dispensers an ice flow
restrictor is available. This ice flow restrictor decreases
the amount of ice allowed to enter the ice chute by block-
ing a small area at the entrance of the dispenser chute.
This in turn restricts the flow of ice that is dispensed in to
your cup.
Please refer to the instructions included in kit #5013822
for more information on how to install.
6" (15.2 cm)
clearance
for cuber
cuber
3
4
3
2
4
6"
(15.2 cm)
6"
(15.2 cm)
6" (15.2 cm)
6" (15.2 cm)
1
5
Содержание MD 150
Страница 12: ...12 INSTALLATION COLD CARB BAG IN BOX B I B SYSTEM ...
Страница 16: ...16 INSTALLATION MD 150 6 VALVE PLUMBING DIAGRAM MD 150 6 VALVE FLEX MANIFOLD ...
Страница 17: ...Installation and Service Manual 17 INSTALLATION MD 175 8 VALVE PLUMBING DIAGRAM MD 175 8 VALVE FLEX MANIFOLD ...
Страница 18: ...18 INSTALLATION MD 200 250 8 VALVE PLUMBING DIAGRAM MD 200 250 8 VALVE FLEX MANIFOLD ...
Страница 20: ...20 INSTALLATION MD 302 12 VALVE PLUMBING DIAGRAM LEFT RIGHT MD 302 12 VALVE FLEX MANIFOLD 1 PER SIDE ...
Страница 22: ...22 INSTALLATION MD 402 20 VALVE PLUMBING DIAGRAMS MD 402 20 VALVE FLEX MANIFOLD 1 PER SIDE LEFT RIGHT ...
Страница 42: ...42 EXPLODED VIEWS PARTS DIAGRAMS MD 150 175 200 250 EXPLODED VIEW ...
Страница 43: ...Installation and Service Manual 43 EXPLODED VIEWS PARTS DIAGRAMS MD 150 PARTS LIST MD 175 PARTS LIST ...
Страница 44: ...44 EXPLODED VIEWS PARTS DIAGRAMS MD 200 250 PARTS LIST ...
Страница 45: ...Installation and Service Manual 45 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 402 EXPLODED VIEW ...
Страница 46: ...46 EXPLODED VIEWS PARTS DIAGRAMS MDH 302 PARTS LIST MDH 402 PARTS LIST ...
Страница 55: ...Installation and Service Manual 55 EXPLODED VIEWS PARTS DIAGRAMS MDH 402 115V WIRING DIAGRAM ...
Страница 61: ......
Страница 62: ...Installation and Service Manual ...