Section 2
Installation Instructions
Part Number 5030763
5/11
2-3
Location
The location selected for the beverage dispenser must
meet the following criteria. If any of these criteria are not
met, select another location.
•
The air temperature must be at least 50°F (10°C), but
must not exceed 95°F (35°C).
•
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
•
The countertop must be level. Verify that the
countertop can support the weight of the dispenser.
•
Water lines, drains and power outlet must be within 6'
(1.8 m) of location.
Pre-installation Checklist
When installing any system, first make sure the major
components are available. Generally the major
components necessary for an installation are:
Pre-mix System:
B-I-B System also:
Post Mix System:
Bulk Syrup System also:
!
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure
to a high concentration of CO
2
gas causes tremors,
which are followed rapidly by loss of consciousness
and suffocation. If a CO
2
gas leak is suspected,
particularly in a small area, immediately ventilate the
area before repairing the leak. CO
2
lines and pumps
must not be installed in an enclosed space. An
enclosed space can be a cooler or small room or
closet. This may include convenience stores with
glass door self serve coolers. If you suspect CO
2
may build up in an area, venting of the B-I-B pumps
and / or CO
2
monitors must be utilized.
CO
2
regulator set
Product connectors for Figal tank
Gas connectors for Figal tank
Beverage dispenser
Beverage tubing
CO
2
tank
Figal beverage tanks
Stepless (Oetiker) clamps
Chain for CO
2
tank
B-I-B connectors
B-I-B regulator set
B-I-B rack
B-I-B syrup boxes
CO
2
regulator set
Beverage dispenser
Beverage tubing
CO
2
tank
Carbonator
Stepless (Oetiker) clamps
Chain for CO
2
tank
Syrup connectors for Bulk tank
Gas connectors for Bulk tank
Bulk syrup tanks