background image

Installation Instructions

Section 2

2-4

Part Number 5030763

5/11

Electrical

GENERAL

MINIMUM CIRCUIT AMPACITY

The minimum circuit ampacity is used to help select the 
wire size of the electrical supply. (Minimum circuit 
ampacity is not the beverage/ice machine’s running amp 
load.) The wire size (or gauge) is also dependent upon 
location, materials used, length of run, etc., so it must be 
determined by a qualified electrician.

ELECTRICAL REQUIREMENTS

Refer to Ice Machine Model/Serial Plate for 
voltage/amperage specifications.

MINIMUM CIRCUIT AMPERAGE CHART

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of 
malfunction or breakdown, grounding provides a path of 
least resistance for electric current to reduce the risk of 
electric shock. This appliance is equipped with a cord 
having an equipment-grounding conductor and a 
grounding plug. The plug must be plugged into an 
appropriate outlet that is properly installed and grounded 
in accordance with all local codes and ordinances.

!

Warning

All wiring must conform to local, state and national
codes.

Important

Due to continuous improvements, this information is
for reference only. Please refer to the dispenser
serial number tag to verify electrical data. Serial tag
information overrides information listed on this page.

Dispenser

Voltage

 Amps

Beverage Tower, 

Model 2P FS, 

464 Tower

24V AC

2.4

(Remote Mount)

!

Warning

The beverage/ice machine must be grounded in
accordance with national and local electrical codes.

!

Warning

Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment
grounding conductor. If repair or replacement of the cord or
plug is necessary, do not connect the equipment-
grounding conductor to a live terminal. Check with a
qualified electrician or serviceman if the grounding
instructions are not completely understood, or if in doubt as
to whether the appliance is properly grounded. Do not
modify the plug provided with the appliance — if it will not fit
the outlet, have a proper outlet installed by a qualified
electrician.

!

Warning

When using electric appliances, basic precautions must
always be followed, including the following:

a. Read all the instructions before using the appliance.

b. To reduce the risk of injury, close supervision is 

necessary when an appliance is used near children.

c. Do not contact moving parts.

d. Only use attachments recommended or sold by the 

manufacturer.

e. Do not use outdoors.

f. For a cord-connected appliance, the following shall 

be included:

• Do not unplug by pulling on cord. To unplug, 

grasp the plug, not the cord.

• Unplug from outlet when not in use and before 

servicing or cleaning.

• Do not operate any appliance with a damaged 

cord or plug, or after the appliance malfunctions or 
is dropped or damaged in any manner. Contact 
the nearest authorized service facility for 
examination, repair, or electrical or mechanical 
adjustment.

g. For a permanently connected appliance — Turn the 

power switch to the off position when the appliance is 
not in use and before servicing or cleaning.

h. For an appliance with a replaceable lamp — Always 

unplug before replacing the lamp. Replace the bulb 
with the same type.

i. For a grounded appliance — Connect to a properly 

grounded outlet only. See Grounding Instructions.

Содержание 2703329

Страница 1: ...Manual This manual is updated as new information and models are released Visit our website for the latest manual www manitowocfsg com Leader in Ice Beverage Dispensers BEVERAGE FLAVOR SHOT TOWERS Par...

Страница 2: ...sure to read the Warning statement before proceeding and work carefully Caution Text in a Caution box alerts you to a situation in which you could damage the equipment Be sure to read the Caution sta...

Страница 3: ...n 2 Installation Instructions General 2 1 Dimensions 2 1 Footprint 2 2 Location 2 3 Pre installation Checklist 2 3 Electrical 2 4 General 2 4 Minimum Circuit Ampacity 2 4 Electrical Requirements 2 4 M...

Страница 4: ...Back Room Package 3 3 Racking 3 4 B I B 3 4 Pumps 3 4 Auto Bag Selectors 3 4 Figal System 3 4 Figal Tanks 3 4 Section 4 Maintenance Cleaning 4 1 Daily Cleaning 4 1 MONTHLY SANITIZING 4 1 Cleaning Che...

Страница 5: ...__________ Distributor Telephone Number ____________________ Model Number _______________________________ Serial Number ________________________________ Installation Date _____________________________...

Страница 6: ...pecifically excludes all beverage valve brixing general adjustments cleaning accessories and related servicing Your warranty card must be returned to MBE to activate the warranty on this equipment If...

Страница 7: ...ller Contact your Manitowoc Beverage Equipment Service Agent or call Manitowoc Beverage Equipment for information regarding start up services Dimensions Important Failure to follow these installation...

Страница 8: ...Installation Instructions Section 2 2 2 Part Number 5030763 5 11 Footprint OPTIONAL 2 5 CUT OUT FOR SYRUP LINES OPTIONAL 1 1 4 CUT OUT FOR DRAIN LINE OPTIONAL 3 16 HOLES FOR MOUNTING SCREWS...

Страница 9: ...rbon Dioxide CO2 displaces oxygen Exposure to a high concentration of CO2 gas causes tremors which are followed rapidly by loss of consciousness and suffocation If a CO2 gas leak is suspected particul...

Страница 10: ...ck The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the cord or plug is necessary do...

Страница 11: ...for syrup water lines drain line if used and mounting screws 4 Cut the holes for the incoming water syrup and if used drain lines 5 Drain line A If a drain line is desired carefully remove end from 3...

Страница 12: ...ressure regulators must be set at 60 PSI Diet pre mix pressure regulators must be set at 40 PSI If you are experiencing high foaming decreasing the pressures may correct the problem Spitting and poppi...

Страница 13: ...ant procedure and best practice to address cleaning to deliver the best quality drink to your customer Clean and sanitize the water and syrup circuits according to instructions provided in this manual...

Страница 14: ...Operation Section 3 3 2 Part Number 5030763 5 11 Component Identification Valve nozzle and diffusers Soda or Flavor Shot Valves Key Switch Drainpan Grid Drain Pan Splash Panel...

Страница 15: ...r in the tank under high pressure creates the soda water The quality of carbonation percent of CO2 mixed in the water increases as the water temperature decreases and exposure time increases The water...

Страница 16: ...fers to a plastic disposable bag The B I B normally contains 5 gallons of syrup however some locations offer 2 1 2 gallon B I B units This plastic bag is then held inside a cardboard or other containe...

Страница 17: ...e nozzle and diffuser with soap and water to remove syrup residue A soft bristle brush can be used 8 Rinse nozzle and diffuser with warm clean water 9 Replace diffuser in the valve body Position nozzl...

Страница 18: ...panel Clean the valve nozzles and diffusers Preventive Maintenance Preventative maintenance is a vital part of keeping your dispenser in top condition Following the guidelines below will assist you in...

Страница 19: ...nitizer Bag In Box bag connector 1 Prepare the following in the buckets Bucket 1 warm to hot tap water for rinsing Bucket 2 mild detergent and warm to hot water Bucket 3 mix a solution of unscented bl...

Страница 20: ...y 100 PPM available chlorine 1 4 oz bleach to 1 gallon water 2 Disconnect all product and water lines from product tanks and remove carbonator 3 Locate the Figal syrup tank for the circuit to be sanit...

Страница 21: ...place HP regulator CO2 line pinched kinked or obstructed Check repair replace CO2 line One valve will not dispense anything Is there power to the valve Broken wire or loose connection Replace repair w...

Страница 22: ...Before Calling for Service Section 5 5 2 Part Number 5030763 5 11 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 23: ......

Страница 24: ...ure Drive Sellersburg IN 47172 USA Ph 812 246 7000 Fax 812 246 7024 Visit us online at www manitowocfsg com 2011 Manitowoc Continuing product improvements may necessitate change of specifications with...