Page 28
UltraWave Product Guide
Stacking UltraWave units
To increase the height of the microwave field, it is possible to stack two, or three, UltraWave units
on one mounting post. Use the UCM Height Calc tool to determine the required mounting heights
and mounting angles for the stacked units. Each UltraWave sensor must use a different Frequency
Pair. To ensure maximum signal isolation, use Frequency Pairs that are at least two numbers
apart. Do not use Frequency Pairs that are adjacent, consecutive numbers (e.g., use Frequency
Pairs 1, 3, 5, rather than 1, 2, 3). To facilitate the wiring connections, it is recommended that the
receivers be mounted on one post, and the transmitters be mounted on another post.
illustrates the wiring connections for a double stacked UltraWave configuration.
illustrates
a triple stack UltraWave system.
Figure 26: Silver Network Ethernet wiring diagram
maximum 60 receivers/processors
first receiver or
second receiver
last receiver
Network
max. cable run
third receiver
fourth receiver
fifth receiver
Manager
computer
security
management
system
computer
between receiver
or processor and
Category 5 Ethernet cable
class 3
PoE
switch
processor
or processor
or processor
or processor
or processor
or processor
(328 ft.)
PoE switch 100 m