SU320CSX
4110-0446, Rev. C
Page 67 of 96
© 2017 UTC
Aerospace Systems
Date Printed: 3-Jan-2017
This document does not contain any export controlled technical data.
Setting Type
Global
Command
TEC:ENABLE
state
Parameters
state
Return Values
none
Range
ON
Enables TEC
OFF
Disables TEC
Type
string
Example
TEC:ENABLE ON
5.15.6.
Get Thermoelectric Cooler State
Description
Returns the state of the thermoelectric cooler.
Setting Type
Global
Command
TEC:ENABLE?
Parameters
state
Return Values
none
Range
ON
TEC Enabled
OFF
TEC Disabled
Type
string
Example
TEC:ENABLE? -- query command
ON -- return value
5.15.7.
Wait for TEC Lock
Description
Blocks operation of camera until TEC is locked. Useful in cases
where passed data needs to be properly stabilized, such as in
performing an updated background correction file. Camera
operation is prevented for up to 60 seconds, and will unblock when
a stable TEC lock signal is achieved. Queries while blocked are not
received.
Setting Type
Global
Command
TEC:WAIT
Parameters
none
Return Values
none
Range
none