SU320CSX
4110-0446, Rev. C
Page 20 of 96
© 2017 UTC
Aerospace Systems
Date Printed: 3-Jan-2017
This document does not contain any export controlled technical data.
3.
Camera Link Data Interface
The digital data interface to the camera is through a base Camera Link compatible interface using low-
voltage differential signaling (LVDS). Sensors Unlimited cameras can be interfaced to most frame
grabbers, and they have verified operation with National Instruments cards.
PoCL ‘Power over Camera Link’ is not employed and special PoCL cables are not required. However,
PoCL cables are compatible.
Table 3. Digital output 26-pin connector (3M 12226-1150-00FR) signal assignment. (standard Camera Link protocol)
1
Inner shield (camera GND)
20
SerTC-
14
Inner shield (camera GND)
8
SerTFG-
2
X0-
21
15
X0+
9
CC1-
3
X1-
22
CC1+
16
X1+
10
No connect
4
X2-
23
No connect
17
X2+
11
No connect
5
Xclk-
24
No connect
18
Xclk+
12
No connect
6
X3-
25
No connect
19
X3+
13
Inner shield (camera GND)
7
SerTC+
26
Inner shield (camera GND)