![Sensata Magnum Energy MS Series Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/sensata/magnum-energy-ms-series/magnum-energy-ms-series_owners-manual_1243184078.webp)
© 2016 Sensata Technologies
Page 68
Appendix C – Power Consumption & Output Waveforms
TIME
V
O
L
T
A
G
E
40
80
0
120
40
160
200
80
120
160
200
Modified
Sine Wave
Sine Wave
Square Wave
C-2 Output Waveform
The inverter’s output waveform is the shape of the wave that alternating current makes as its
voltage rises and falls with time (see Figure C-1 below). The three basic output waveforms are:
Figure C-1, AC Waveforms
• Modifi ed Sine Wave
– Also referred to as
a “quasi sine wave” or a “modifi ed square
wave”. This output looks like a one-step
staircase and the waveform changes its
width to continually provide the correct
RMS output voltage regardless of the
battery voltage. Most loads that run from a
sine wave will also run from a modifi ed sine
wave. However, things such as clocks and
furnace controllers may have trouble.
• Sine Wave
– An AC waveform that looks
like rolling waves on water. It rises and falls
smoothly with time. The grid puts out a sine
waveform. Any plug-in AC equipment will
operate from a sine wave output inverter.
• Square Wave
– The simplest AC waveform.
Some types of equipment behave strangely
when powered from a square wave inverter.
Appendix C – Power Consumption & Output Waveforms
C-1 Appliances and Run Time
The MS Series inverter/charger can power a wide range of household appliances including small
motors, hair dryers, clocks, and other electrical devices. As with any appliance using batteries for
power, there is a certain length of time that it can run—this is called “run time.” Actual run time
depends on several variables including the size and the type of appliance, the type of batteries
installed in your application, as well as the battery’s capacity and age. Other factors such as the
battery’s state of charge and temperature can also aff ect the length of time your appliances can run.
Appliances (TVs, VCRs, stereos, computers, coff ee pots, incandescent lights, and toasters) can all
be successfully powered by your inverter. Larger electrical appliances, however, such as stoves,
water heaters, etc., can quickly drain your batteries and are not recommended for this application.
All electrical appliances are rated by the amount of power they consume (see Table C-1). The
rating is printed on the product’s nameplate label, usually located on its chassis near the AC
power cord. Even though it is diffi
cult to calculate exactly how long an inverter will run a particular
appliance, the best advice is trial and error. Your MS Series inverter has a built-in safeguard that
automatically protects your batteries from over-discharge.
Info
: For optimum performance, a minimum battery bank of 200 AH is recommended
for moderate loads (<1000W) and greater than 400 AH for heavy loads (≥1000W).
Table C-1, Typical Appliance Power Consumption
Device
Load
Device
Load
Device
Load
Blender
400W
Coff ee Maker
1200W
Light (Flo)
10W
Computer
300W
Color TV
150W
Light (Inc)
100W
Drill
500W
Hair Dryer
1000W
Microwave
1000W
Hot Plate
1800W
Iron
1000W
Refrigerator
500W
Содержание Magnum Energy MS Series
Страница 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Страница 22: ...Page 12 2016 Sensata Technologies Installation Figure 2 4 MS Dimensions MS2012 MS2812 MS2024 MS4024 MS4048...
Страница 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Страница 26: ...Page 16 2016 Sensata Technologies Installation Figure 2 6 DC and Battery Temperature Sensor Wiring...
Страница 38: ...Page 28 2016 Sensata Technologies Installation Figure 2 13 AC Wiring for Single In Dual Out Con gurations...
Страница 39: ...2016 Sensata Technologies Page 29 Installation Figure 2 14 AC Wiring for Dual In Single Out Con gurations...
Страница 40: ...Page 30 2016 Sensata Technologies Installation Figure 2 15 AC Wiring for Dual In Dual Out Con gurations...
Страница 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Страница 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...