Operation
3.3 Battery Charging
The MS Series is equipped with a PFC (Power Factor Corrected) and PI (Proportional-Integral)
multi-stage battery charger. The PFC feature controls the amount of power used to charge the
batteries to obtain a power factor as close as possible to 1 (or unity). This causes the battery charger
to look like a resistor to the line (forces the charge current wave shape to mirror the voltage wave
shape). The PI feature allows the charger voltage and current to change independently. These two
features maximize the real power available from the AC power source (i.e., utility or generator),
which translates into less power wasted and increased charging capabilities.
When an AC source is connected to the AC input, the inverter begins monitoring for acceptable AC
voltage. Once the AC voltage is accepted, the AC transfer relay closes the charge mode begins.
After the charge mode begins, the inverter’s battery voltage is monitored to determine the charging
stage. If the battery voltage is low (≤12.8 VDC/12-volt models, ≤25.6 VDC/24-volt models, or
≤51.2 VDC/48-volt models), the charger begins Bulk charging. If the DC voltage is high (>12.8
VDC/12-volt models, >25.6 VDC/ 24-volt models, or >51.2 VDC/48-volt models), the charger will
skip the Bulk and Absorb charge stages and go directly to Float charging. However, if the incoming
AC power is lost and returns within 2 minutes the charge mode returns to the charge stage it was
in prior to losing AC input—regardless of the battery voltage.
The multi-stage charger in the MS Series can use up to fi ve diff erent charging stages to help
monitor and keep the batteries healthy. The fi ve stages include an automatic 4-stage charging
process (Figure 3-7)—Bulk, Absorb, Float, and Full Charge—and a manual Equalization (EQ) charge
stage. The automatic 4-stage charge process provides complete recharging and monitoring of the
batteries without damage due to overcharging. The EQ stage (requires a remote control display
to enable) can be used to stir up stratifi ed electrolyte and to reverse any battery plate sulfation
that may have occurred—if recommended by your battery’s manufacturer.
While charging, the unit may go into charger back-off protection, which automatically reduces the
charge current to the batteries. This is caused by: 1) The internal temperature is too hot – the
charger automatically reduces the charge rate to maintain temperature; or 2) The AC input voltage
falls below 90 VAC – the charger will stop charging to help stabilize the incoming AC voltage.
Figure 3-6, Power Flow – Standby Mode (MS2000-15B/-20B models)
AC NEU OUT
Neutral-Ground
Transfer Contact
AC Hot
Transfer Contact
AC HOT 1 OUT
AC HOT 1 IN
INPUT
(30A)
AC NEU IN
AC GROUND
DC
IN
Power Transformer
FET Bridge
AC
DC
DC POS
DC NEG
AC
OUT
AC HOT 2 OUT
CB1
CB2
120 VAC
120 VAC
AC
IN
Содержание Magnum Energy MS Series
Страница 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Страница 22: ...Page 12 2016 Sensata Technologies Installation Figure 2 4 MS Dimensions MS2012 MS2812 MS2024 MS4024 MS4048...
Страница 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Страница 26: ...Page 16 2016 Sensata Technologies Installation Figure 2 6 DC and Battery Temperature Sensor Wiring...
Страница 38: ...Page 28 2016 Sensata Technologies Installation Figure 2 13 AC Wiring for Single In Dual Out Con gurations...
Страница 39: ...2016 Sensata Technologies Page 29 Installation Figure 2 14 AC Wiring for Dual In Single Out Con gurations...
Страница 40: ...Page 30 2016 Sensata Technologies Installation Figure 2 15 AC Wiring for Dual In Dual Out Con gurations...
Страница 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Страница 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...