Page 4
© 2016 Sensata Technologies
Introduction
Figure 1-2, Electrical Connection Points
Positive (+)
DC Terminal
(under cover)
Negative (-)
DC Terminal
(under cover)
Mounting
Flange
DC
Equipment
Ground
Terminal
AC Entry/
Exit
Connections
Intake Air Vents
(and on right front side)
7
DC Equipment Ground Terminal
– this connection is used to tie the exposed chassis
of the inverter to the DC grounding system. This terminal accepts CU/AL conductors from
#14 to #2 AWG (2.1 to 33.6 mm2). Tightening torque is 45 in-lb.
8
AC Entry/Exit Connections
– two 3/4” knockouts provided with cable-clamp strain
reliefs to accommodate and secure the AC input and output fi eld wiring.
9
Intake Air Vents
– ventilation openings to pull in air to help keep the inverter cool for
peak performance.
10
Positive DC Terminal
– provides a 360 degree connection point for the positive (+) cable
from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that holds the
battery cable to the DC terminal.
11
Negative DC Terminal
– provides a 360 degree connection point for the negative (–)
cable from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that
holds the battery cable to the DC terminal.
12
Mounting Flange
– used to secure the inverter to a shelf or wall.
Содержание Magnum Energy MS Series
Страница 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Страница 22: ...Page 12 2016 Sensata Technologies Installation Figure 2 4 MS Dimensions MS2012 MS2812 MS2024 MS4024 MS4048...
Страница 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Страница 26: ...Page 16 2016 Sensata Technologies Installation Figure 2 6 DC and Battery Temperature Sensor Wiring...
Страница 38: ...Page 28 2016 Sensata Technologies Installation Figure 2 13 AC Wiring for Single In Dual Out Con gurations...
Страница 39: ...2016 Sensata Technologies Page 29 Installation Figure 2 14 AC Wiring for Dual In Single Out Con gurations...
Страница 40: ...Page 30 2016 Sensata Technologies Installation Figure 2 15 AC Wiring for Dual In Dual Out Con gurations...
Страница 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Страница 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...