![Sensata Magnum Energy MS Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/sensata/magnum-energy-ms-series/magnum-energy-ms-series_owners-manual_1243184064.webp)
Page 54
© 2016 Sensata Technologies
Operation
3.9 Inverter Fan Operation
The inverter contains two internal cooling fans that are automatically controlled. The speed of
these fans is determined either by the internal temperature of the inverter or by the load on the
inverter. The inverter’s fans will come on under the conditions listed below:
• Fans run full speed if the internal transistors (FETS) or the power transformer reaches 80°C
degrees Celsius (176°F), or the inverter is running at 100% of its rated load.
• Fans run medium speed if the internal transistors (FETS) or the power transformer reaches
60°C (140°F), or the inverter is running at 50% of its rated load.
• Fans run low speed when the inverter is running at 25% of its rated load.
The fans shut down when none of the above conditions are met, or if the battery voltage is below
9.5V (12-volt systems)/19.0V (24-volt systems)/38V (48-volt models).
Whenever the inverter is fi rst connected to the battery, the fans come on for about one second.
Info:
The inverter’s fans will not come on based on temperature sensed by the optional
Battery Temperature Sensor.
3.10 Using a Remote with the MS Series Inverter
The MS Series inverter—when connected to a remote control display (i.e., ME-RC, ME-ARC)—has
many advanced features. The inverter and remote communicate with each other to allow these
advanced features to be set up or enabled. However, the remote may have a later/newer software
revision than the inverter, so some of the features and functionality in the remote may not be
available with your inverter.
Use the steps below to determine what remote menus/features are available with your inverter:
1. Obtain your inverter’s software revision.
Note:
To view the inverter’s software revision level, push the TECH button on your remote and
access the Revisions menu.
2. Use the chart below to determine the inverter’s compatibility level (L1, L2, L3 or L4) based on
your inverter’s software revision.
Table 3-3, Inverter Compatibility Level
INV/CHG
Models
Level 1
(L1)
Level 2
(L2)
Level 3
(L3)
Level 4
(4)
MS2000 (–xxB)
≥ Rev 2.6
≥ Rev 3.6
≥ Rev 4.2
≥ Rev 5.4
MS2012 (–xxB)
≥ Rev 2.6
≥ Rev 3.6
≥ Rev 4.2
≥ Rev 5.4
MS2812
≥ Rev 2.6
≥ Rev 3.6
NA
≥ Rev 5.4
MS2024
NA
NA
NA
≥ Rev 5.0
MS4024
≥ Rev 2.6
≥ Rev 3.6
NA
≥ Rev 5.4
MS4048 (–20B)
NA
NA
NA
≥ Rev 5.7
3. After determining the inverter’s compatibility level, refer to the remote’s compatibility matrix
(fi nd it online at: www.SensataPower.com under the References menu) to determine which
remote features/settings you can use based on your inverter’s compatibility level.
Note:
If your inverter’s compatibility level is the same or greater than the ‘Inverter Model/Level
Required’ on the remote compatibility matrix on our website, then your inverter can support the
device setting/feature you want. If your inverter does not have the required compatibility level for
a feature/setting you want, contact Sensata to determine if there is a software upgrade option for
your inverter.
Содержание Magnum Energy MS Series
Страница 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Страница 22: ...Page 12 2016 Sensata Technologies Installation Figure 2 4 MS Dimensions MS2012 MS2812 MS2024 MS4024 MS4048...
Страница 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Страница 26: ...Page 16 2016 Sensata Technologies Installation Figure 2 6 DC and Battery Temperature Sensor Wiring...
Страница 38: ...Page 28 2016 Sensata Technologies Installation Figure 2 13 AC Wiring for Single In Dual Out Con gurations...
Страница 39: ...2016 Sensata Technologies Page 29 Installation Figure 2 14 AC Wiring for Dual In Single Out Con gurations...
Страница 40: ...Page 30 2016 Sensata Technologies Installation Figure 2 15 AC Wiring for Dual In Dual Out Con gurations...
Страница 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Страница 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...